English
Language : 

AMC1210 Datasheet, PDF (26/47 Pages) Burr-Brown (TI) – Quad Digital Filter for 2nd-Order Delta-Sigma Modulator
AMC1210
SBAS372A – APRIL 2006 – REVISED OCTOBER 2006
www.ti.com
REGISTER MAP
Filter Module 1
Filter Module 2
Filter Module 3
Filter Module 4
Data/Time Output
ADDRESS
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x08
0x09
0x0A
0x0B
0x0C
0x0D
0x0E
0x0F
0x10
0x11
0x12
0x13
0x14
0x15
0x16
0x17
0x18
0x19
0x1A
0x1B
0x1C
0x1D
0x1E
0x1F
0x20
0x21
0x22
0x23
0x24
0x25 to 0x7F
RESET VALUE
0x0000
0x0000
0x0000
0x0000
0x7FFF
0x0000
0x0000
0x0000
0x0000
0x0000
0x7FFF
0x0000
0x0000
0x0000
0x0000
0x0000
0x7FFF
0x0000
0x0000
0x0000
0x0000
0x0000
0x7FFF
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000/0x00000000 (1)
0x0000
0x0000/0x00000000 (1)
0x0000
0x0000/0x00000000 (1)
0x0000
0x0000/0x00000000 (1)
0x0000
0x0000
NAME
Interrupt Register
Control Parameter Register for Filter Module 1
Sinc Filter Parameter Register for Filter Module 1
Integrator Parameter Register for Filter Module 1
High-level Threshold Register for Filter Module 1
Low-level Threshold Register for Filter Module 1
Comparator Parameter Register for Filter Module 1
Control Parameter Register for Filter Module 2
Sinc Filter Parameter Register for Filter Module 2
Integrator Parameter Register for Filter Module 2
High-level Threshold Register for Filter Module 2
Low-level Threshold Register for Filter Module 2
Comparator Parameter Register for Filter Module 2
Control Parameter Register for Filter Module 3
Sinc Filter Parameter Register for Filter Module 3
Integrator Parameter Register for Filter Module 3
High-level Threshold Register for Filter Module 3
Low-level Threshold Register for Filter Module 3
Comparator Parameter Register for Filter Module 3
Control Parameter Register for Filter Module 4
Sinc Filter Parameter Register for Filter Module 4
Integrator Parameter Register for Filter Module 4
High-level Threshold Register for Filter Module 4
Low-level Threshold Register for Filter Module 4
Comparator Parameter Register for Filter Module 4
Control Register
Pattern Register
Clock Divider Register
Status Register
Data Register for Filter Module 1(1)
Time Register for Filter Module 1
Data Register for Filter Module 2(1)
Time Register for Filter Module 2
Data Register for Filter Module 3(1)
Time Register for Filter Module 3
Data Register for Filter Module 4(1)
Time Register for Filter Module 4
Not used. Read will return 0x0000
(1) The Data Registers can also be represented as 32-bit.
All control parameters are stored in the register map. Additionally, the status of the AMC1210 is read out
through the register map. The mnemonic in the succeeding register description is given in Example 1.
26
Submit Documentation Feedback