SWITCHING CHARACTERISTICS over COMMERCIAL operating ranges
Clock (20 MHz and 25 MHz)
Parameter
No. Symbol
Description
CLKIN Requirements
36
tCKIN X1 Period(a)
37
tCLCK X1 Low Time (1.5 V)(a)
38 tCHCK X1 High Time (1.5 V)(a)
39
tCKHL X1 Fall Time (3.5 to 1.0 V)(a)
40
tCKLH X1 Rise Time (1.0 to 3.5 V)(a)
CLKOUT Timing
42 tCLCL CLKOUTA Period
43 tCLCH CLKOUTA Low Time (CL=50
pF)
44 tCHCL CLKOUTA High Time (CL=50
pF)
45 tCH1CH2 CLKOUTA Rise Time
(1.0 to 3.5 V)
46 tCL2CL1 CLKOUTA Fall Time
(3.5 to 1.0 V)
61 tLOCK Maximum PLL Lock Time
69 tCICOA X1 to CLKOUTA Skew
70 tCICOB X1 to CLKOUTB Skew
20 MHz
Min
50
15
15
50
0.5tCLCL – 2 = 23
0.5tCLCL – 2 = 23
Preliminary
25 MHz
Max
Min
60
40
15
15
5
5
40
0.5tCLCL – 2 = 18
0.5tCLCL – 2 = 18
3
3
1
15
25
Max
60
5
5
3
3
1
15
25
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ms
ns
ns
Notes:
All timing parameters are measured at 1.5 V with 50 pF loading on CLKOUTA, unless otherwise noted. All output test conditions
are with CL =50 pF. For switching tests, VIL=0.45 V and VIH =2.4 V, except at X1 where VIH =VCC – 0.5 V.
a The specifications for CLKIN are applicable to the normal PLL and CLKDIV2 modes.
The PLL should be used for operations from 16.667 MHz to 40 MHz. For operations below 16.667 MHz, the CLKDIV2
mode should be used.
Because the CLKDIV2 input frequency is two times the system frequency, the specifications for twice the frequency should
be used for CLKDIV2 mode. For example, use the 20 MHz CLKIN specifications for 10 MHz operation.
Am186/188ES and Am186/188ESLV Microcontrollers
89