English
Language : 

AM188ES-40KCW Datasheet, PDF (83/102 Pages) Advanced Micro Devices – High Performance, 80C186-/80C188-Compatible and 80L186-/80L188-Compatible, 16-Bit Embedded Microcontrollers
PRELIMINARY
SWITCHING CHARACTERISTICS over COMMERCIAL operating ranges
Interrupt Acknowledge Cycle (20 MHz and 25 MHz)
Parameter
No. Symbol
Description
General Timing Requirements
1
tDVCL Data in Setup
2
tCLDX Data in Hold
General Timing Responses
3
tCHSV Status Active Delay
4
tCLSH Status Inactive Delay
7
tCLDV Data Valid Delay
8
tCHDX Status Hold Time
9
tCHLH ALE Active Delay
10
tLHLL ALE Width
11 tCHLL ALE Inactive Delay
12 tAVLL AD Address Invalid to ALE
Low(a)
15 tCLAZ AD Address Float Delay
19
tDXDL DEN Inactive to DT/R Low(a)
20 tCVCTV Control Active Delay 1(b)
21 tCVDEX DEN Inactive Delay
22 tCHCTV Control Active Delay 2(c)
23 tLHAV ALE High to Address Valid
31 tCVCTX Control Inactive Delay(b)
68 tCHAV CLKOUTA High to A
Address Valid
Preliminary
20 MHz
25 MHz
Min
Max
Min
Max Unit
10
10
ns
3
3
ns
0
25
0
20 ns
0
25
0
20 ns
0
25
0
20 ns
0
0
ns
25
20 ns
tCLCL – 10 = 40
tCLCL – 10 = 30
ns
25
20 ns
tCLCH
tCLCH
ns
tCLAX = 0
25
tCLAX = 0
20 ns
0
0
ns
0
25
0
20 ns
0
25
0
20 ns
0
25
0
20 ns
20
15
ns
0
25
0
20 ns
0
25
0
20 ns
Notes:
All timing parameters are measured at 1.5 V with 50 pF loading on CLKOUTA, unless otherwise noted. All output test conditions
are with CL =50 pF. For switching tests, VIL=0.45 V and VIH =2.4 V, except at X1 where VIH =VCC – 0.5 V.
a Testing is performed with equal loading on referenced pins.
b This parameter applies to the INTA1–INTA0 signals.
c This parameter applies to the DEN and DT/R signals.
Am186/188ES and Am186/188ESLV Microcontrollers
83