HC20K400 Datasheet, PDF (21/36 Pages) Altera Corporation – HardCopy APEX Device Family | |||
|
◁ |
10. Operating Conditions
H51010-2.3
Recommended
Operating
Conditions
Tables 10â1 through 10â4 provide information on absolute maximum
ratings, recommended operating conditions, DC operating conditions,
and capacitance for 1.8-V HardCopy® APEXTM devices.
Table 10â1. HardCopy APEX Device Absolute Maximum Ratings Note (1)
Symbol
Parameter
V CCINT
V CCIO
VI
I OUT
T STG
TAMB
TJ
Supply voltage
DC input voltage
DC output current, per pin
Storage temperature
Ambient temperature
Junction temperature
Conditions
With respect to ground (2)
No bias
Under bias
BGA packages, under bias
Table 10â2. HardCopy APEX Device Recommended Operating Conditions
Symbol
Parameter
Conditions
V CCINT
V CCIO
VI
VO
TJ
Supply voltage for internal
logic and input buffers
Supply voltage for output
buffers, 3.3-V operation
Supply voltage for output
buffers, 2.5-V operation
Input voltage
Output voltage
Junction temperature
(3), (4)
(3), (4)
(3), (4)
(2), (5)
For commercial use
For industrial use
tR
Input rise time (10% to 90%)
tF
Input fall time (90% to 10%)
Min
Max Unit
â0.5
2.5
V
â0.5
4.6
V
â0.5
4.6
V
â25
25
mA
â65
150
°C
â65
135
°C
135
°C
Min
1.71
(1.71)
3.00
(3.00)
2.375
(2.375)
â0.5
0
0
â40
Max Unit
1.89
V
(1.89)
3.60
V
(3.60)
2.625 V
(2.625)
4.1
V
V CCIO
V
85
°C
100 ° C
40
ns
40
ns
Altera Corporation
September 2008
10â1
|
▷ |