English
Language : 

EP3C55F780I7 Datasheet, PDF (186/274 Pages) Altera Corporation – This section provides a complete overview of all features relating to the Cyclone III device family
9–28
Chapter 9: Configuration, Design Security, and Remote System Upgrades in the Cyclone III Device Family
Configuration Features
The following are the configurations for the DATA[15..0] bus in a multi-device AP
configuration:
■ Byte-wide multi-device AP configuration
■ Word-wide multi-device AP configuration
Byte-Wide Multi-Device AP Configuration
The simpler method for multi-device AP configuration is the byte-wide multi-device
AP configuration. In the byte-wide multi-device AP configuration, the LSB of the
DATA[7..0]pin from the flash and master device (set to the AP configuration scheme)
is connected to the slave devices set to the FPP configuration scheme, as shown in
Figure 9–9.
Figure 9–9. Byte-Wide Multi-Device AP Configuration
VCCIO (1)
VCCIO (1)
VCCIO (1)
10 kΩ
10 kΩ
VCCIO (2)
10 kΩ
10 kΩ
VCCIO (2)
10 kΩ
CLK
RST#
CE#
OE#
ADV#
WE#
WAIT
DQ[15:0]
A[24:1]
Micron P30/P33 Flash
nCE
nCEO
nCE
GND
DCLK
nRESET
FLASH_nCE
nOE
nAVD
nWE
I/O (5)
DATA[15..0]
PADD[23..0]
MSEL[3..0]
(4)
DQ[7..0]
DATA[7..0]
DCLK
nCEO
nCE
MSEL[3..0]
(4)
DQ[7..0]
DATA[7..0]
DCLK
nCEO
MSEL[3..0]
Cyclone III Master Device
Cyclone III Slave Device
Cyclone III Slave Device
N.C. (3)
(4)
Buffers (6)
Notes to Figure 9–9:
(1) Connect the pull-up resistors to the VCCIO supply of the bank in which the pin resides.
(2) Connect the pull-up resistor to the VCCIO supply voltage of the I/O bank in which the nCE pin resides.
(3) The nCEO pin is left unconnected or used as a user I/O pin when it does not feed the nCE pin of another device.
(4) The MSEL pin settings vary for different configuration voltage standards and POR time. You must set the master device in AP mode and the slave
devices in FPP mode. To connect MSEL[3..0] for the master device in AP mode and the slave devices in FPP mode, refer to Table 9–7 on
page 9–11. Connect the MSEL pins directly to VCCA or GND.
(5) The AP configuration ignores the WAIT signal during configuration mode. However, if you are accessing flash during user mode with user logic,
you can optionally use the normal I/O to monitor the WAIT signal from the Micron P30 or P33 flash.
(6) Connect the repeater buffers between the master device and slave devices for DATA[15..0] and DCLK. All I/O inputs must maintain a maximum
AC voltage of 4.1 V. The output resistance of the repeater buffers must fit the maximum overshoot equation outlined in “Configuration and JTAG
Pin I/O Requirements” on page 9–7.
Cyclone III Device Handbook
Volume 1
August 2012 Altera Corporation