English
Language : 

YGV639 Datasheet, PDF (23/34 Pages) YAMAHA CORPORATION – Video Controller 1 with Enhanced Functions
YGV639
● AC Characteristics
● Measurement Conditions
Input Voltage
Input transition time
Measurement reference voltage:
Output load capacitance
0V / VDD33
1ns (Transition time is specified between VDD33×0.2 and VDD33×0.8.)
Input VIL/VIH
Output VDD33/2V
20pF
Clock Input
No.
Items
Symbol Min.
Typ.
XIN Clock Frequency
1
XIN Clock Cycle Time
fXIN
6
tXIN
25
DTCKIN Clock Frequency
2
DTCKIN Clock Cycle Time
fDTCKIN
tDTCKIN
25
XIN, DTCKIN Clock High Level Pulse
3
Width
twhCLK
7.5
XIN, DTCKIN Clock Low Level Pulse
4
Width
twlCLK
7.5
SYCLK Clock Frequency
5
SYCLK Clock Cycle Time
PLL Out Clock Frequency
6
PLL Out Clock Cycle Time
fSYCLK
tSYCLK
fPLLO
tPLLO
12.03
252
3.01
DCLK Clock Frequency
7
DCLK Clock Cycle Time
fDCLK
tDCLK
25
Note 1) SYCLK is a 1/4 frequency divided internal clock of PLL OUT.
Note 2) DCLK is a dot clock that is used internally.
1, 2
3
4
Max.
40
166
40
Unit Note
MHz
ns
MHz
ns
ns
83.16
332.64
3.96
40
ns
MHz 1
ns 1
MHz 1
ns 1
MHz 2
ns 2
VIH
0.5VDD
VIL
23