English
Language : 

W79E825A Datasheet, PDF (82/127 Pages) Winbond – 8-BIT MICROCONTROLLER
W79E825A/824A/823B/822B Data Sheet
Reception is enabled only if REN is high. The serial port actually starts the receiving of serial data,
with the detection of a falling edge on the RxD pin. The 1-to-0 detector continuously monitors the RxD
line, sampling it at the rate of 16 times the selected baud rate. When a falling edge is detected, the
divide–by-16 counter is immediately reset. This helps to align the bit boundaries with the rollovers of
the divide-by-16 counter.
The 16 states of the counter effectively divide the bit time into 16 slices. The bit detection is done on a
best of three bases. The bit detector samples the RxD pin, at the 8th, 9th and 10th counter states. By
using a majority 2 of 3 voting system, the bit value is selected. This is done to improve the noise
rejection feature of the serial port. If the first bit detected after the falling edge of RxD pin is not 0, then
this indicates an invalid start bit, and the reception is immediately aborted. The serial port again looks
for a falling edge in the RxD line. If a valid start bit is detected, then the rest of the bits are also
detected and shifted into the SBUF.
After shifting in 8 data bits, there is one more shift to do, after which the SBUF and RB8 are loaded
and RI is set. However certain conditions must be met before the loading and setting of RI can be
done.
1. RI must be 0 and
2. Either SM2 = 0, or the received stop bit = 1.
If these conditions are met, then the stop bit goes to RB8, the 8 data bits go into SBUF and RI is set.
Otherwise the received frame may be lost. After the middle of the stop bit, the receiver goes back to
looking for a 1-to-0 transition on the RxD pin.
Figure 16-2: Serial Port Mode 1
- 82 -