English
Language : 

W79E225A_08 Datasheet, PDF (51/203 Pages) Winbond – 8-bit Microcontroller
Preliminary W79E225A/226A/227A Data Sheet
BIT NAME
FUNCTION
Smart fault compare value selector (read/write):
00 = 4
7-6 SCMP [1:0] 01 = 16
10 = 64
11 = 128
Smart fault sampling frequency selector (read/write):
5-4 SFP[1:0]
00 = FOSC/4
01 = FOSC/8
10 = FOSC/16
11 = FOSC/128
Smart fault/brake counter enable (read/write):
3 SFCEN 0 = Disable, and clear internal smart fault counter.
1 = Enable smart fault detector.
Smart fault/brake counter status (read only):
2 SFCST 0 = Counter is non-active.
1 = Counter is active.
Smart fault/brake counters direction status (read only):
1 SFCDIR 0 = Down counting.
1 = Up counting.
0 LSBD
Low level smart brake detector:
0 = Disable low level smart brake detector.
1 = Enable low level smart brake detector. It will be cleared by software.
ADC PIN SELECT
Bit:
7
6
5
4
3
2
1
0
ADCPS.7 ADCPS.6 ADCPS.5 ADCPS.4 ADCPS.3 ADCPS.2 ADCPS.1 ADCPS.0
Mnemonic: ADCPS
Address: C6h
BIT NAME
7-0 ADCPS
FUNCTION
ADC input pin select. There are 8 ADC input pins shared with P1.0~P1.7. Its’
functions are controlled by the bit value in ADCPS. Set the bit to switch the
corresponding pin to ADC input port; clear the bit to disable the pin to perform
ADC input port. The reset value is 00H.
BIT
ADCPS.0
ADCPS.1
ADCPS.2
ADCPS.3
TIMED ACCESS
Bit:
7
TA.7
Mnemonic: TA
CORRESPONDING PIN
P1.0
P1.1
P1.2
P1.3
BIT
ADCPS.4
ADCPS.5
ADCPS.6
ADCPS.7
CORRESPONDING PIN
P1.4
P1.5
P1.6
P1.7
6
TA.6
5
TA.5
4
TA.4
3
TA.3
2
1
TA.2
TA.1
Address: C7h
0
TA.0
- 51 -
Publication Release Date: April 15, 2008
Revision A4.0