W83627EHF_0611 Datasheet, PDF (40/144 Pages) Winbond – WINBOND LPC I/O
W83627EHF/EF, W83627EHG/EG
Table 6.3-3 Relative Register-at Speed Cruise Mode of Smart Fan I control mode
THERMAL- TARGET-SPEED
CRUISE MODE
COUNT
TOLERANCE
KEEP MIN. FAN
OUTPUT VALUE
STEP-
DOWN
TIME
SYSFANOUT CR[05h]
CR[07h]
Bit0-3
CR[12h]
Bit5
CPUFANOUT0 CR[06h]
AUXFANOUT0 CR[13h]
CR[07h]
Bir4-7
CR[14h]
Bit0-3
CR[12h]
Bir4
CR[12h]
Bit3
CR[0Eh]
CPUFANOUT1 CR[63h]
CR[62h]
Bit0-3
CR[12h]
Bit6
STEP-UP
TIME
CR[0Fh]
SMART FANTM III
Concept
SMART FANTM III mode sets a target temperature through BIOS or application software and
W83627EHF/EHG controls the fan speed so that the temperature could meet the target temperature
set in the BIOS or software. Only Pin115 (CPUFANOUT0) and Pin120 (CPUFANOUT1) in
W83627EHF/EHG support SMART FANTM III. Pin115 (CPUFANOUT0) pairs with Pin103 (CPUTIN);
while Pin120 (CPUFANOUT1) pairs with Pin104 (SYSTIN), Pin103 (CPUTIN), or Pin102 (AUXTIN),
which is defined in Bank0 Index 4Ah.bit7~6.
Pin 103
CPUTIN
Pin 104
SYSTIN
Pin 102
AUXTIN
Pin 115
CPUFanOut0
Pin 120
CPUFanOut1
Figure 6.9, 6.10, and 6.11 illustrate SMART FANTM III mode, and the algorithm of fan speed control
is described as follows:
(1) Figure 6.9 shows the initial condition of SMART FANTM III. Target Temperature, Temperature
Tolerance, Maximum Fan Output and Minimum Fan Output must be set first. If the currently
measured temperature is within the (Target Temperature ± Temperature Tolerance), the fan
speed remains constant.
(2) In the case that currently measured temperature goes beyond (Target Temperature +
- 34 -