English
Language : 

W83627EHF_0611 Datasheet, PDF (128/144 Pages) Winbond – WINBOND LPC I/O
W83627EHF/EF, W83627EHG/EG
7.12 Logical Device B (Hardware Monitor, for W83627EHF/EHG only)
CR 30h. (Default 00h)
BIT READ / WRITE
7~1 Reserved.
DESCRIPTION
0: Logical device is inactive.
0
R/W
1: Activate the logical device.
CR 60h, 61h. (Default 00h, 00h)
BIT READ / WRITE
DESCRIPTION
7~0
R/W
These two registers select HM base address <100h : FFEh> on 2 bytes
boundary.
CR 70h. (Default 00h)
BIT READ / WRITE
DESCRIPTION
7~4 Reserved.
3~0
R/W
These bits select IRQ resource for HM.
CR F0h. (VID Control register; Default C1h)
BIT READ / WRITE
DESCRIPTION
VID I/O Control (CRF1[5:0])
7
R/W
0: VID output mode.
1: VID input mode.
6-0 Reserved.
CR F1h. (VID Data Register; Default 00h)
BIT READ / WRITE
7~6 Reserved.
5~0
R/W
VID[5:0] Data Register.
DESCRIPTION
- 122 -