Pulse Width Modulator (PWM)
Bit/Field
13:12
11:10
9:8
Name
ENUPD6
ENUPD5
ENUPD4
Type
R/W
R/W
R/W
Reset
0
Description
PWM6 Enable Update Mode
Value Description
0x0 Immediate
Writes to the PWM6EN bit in the PWMENABLE register are used
by the PWM generator immediately.
0x1 Reserved
0x2 Locally Synchronized
Writes to the PWM6EN bit in the PWMENABLE register are used
by the PWM generator the next time the counter is 0.
0x3 Globally Synchronized
Writes to the PWM6EN bit in the PWMENABLE register are used
by the PWM generator the next time the counter is 0 after a
synchronous update has been requested through the PWM
Master Control (PWMCTL) register.
0
PWM5 Enable Update Mode
Value Description
0x0 Immediate
Writes to the PWM5EN bit in the PWMENABLE register are used
by the PWM generator immediately.
0x1 Reserved
0x2 Locally Synchronized
Writes to the PWM5EN bit in the PWMENABLE register are used
by the PWM generator the next time the counter is 0.
0x3 Globally Synchronized
Writes to the PWM5EN bit in the PWMENABLE register are used
by the PWM generator the next time the counter is 0 after a
synchronous update has been requested through the PWM
Master Control (PWMCTL) register.
0
PWM4 Enable Update Mode
Value Description
0x0 Immediate
Writes to the PWM4EN bit in the PWMENABLE register are used
by the PWM generator immediately.
0x1 Reserved
0x2 Locally Synchronized
Writes to the PWM4EN bit in the PWMENABLE register are used
by the PWM generator the next time the counter is 0.
0x3 Globally Synchronized
Writes to the PWM4EN bit in the PWMENABLE register are used
by the PWM generator the next time the counter is 0 after a
synchronous update has been requested through the PWM
Master Control (PWMCTL) register.
982
January 20, 2012
Texas Instruments-Production Data