English
Language : 

TI380FPAA Datasheet, PDF (9/24 Pages) Texas Instruments – PACKETBLASTERE™
PARAMETER MEASUREMENT INFORMATION
TI380FPAA
PACKETBLASTER ™
SPWS038 – MAY 1997
test measurement
Outputs are driven to a minimum high-logic level of 2.4 V and to a maximum low-logic level of 0.6 V. These levels
are compatible with TTL devices.
Output transition times are specified as follows: for a high-to-low transition on either an input or output signal,
the level at which the signal is said to be no longer high is 2 V, and the level at which the signal is said to be low
is 0.8 V. For a low-to-high transition, the level at which the signal is said to be no longer low is 0.8 V, and the
level at which the signal is said to be high is 2 V, as shown in Figure 2.
The rise and fall times are not specified but are assumed to be those of standard TTL devices, which are typically
1.5 ns.
2 V (high)
0.8 V (low)
Figure 2. Output Transition
The test load circuit shown in Figure 3 represents the programmable load of the tester-pin electronics, which
is used to verify timing parameters of the TI380FPAA output signals.
Tester Pin
Electronics
VLOAD
IOL
CT
IOH
Output
Under
Test
Where:
IOL = 2 mA DC-level verification (all outputs)
IOH = 400 µA (all outputs)
VLOAD = 1.5 V, typical dc-level verification
0.7 V, typical timing verification
CT = 65 pF, typical load-circuit capacitance
Figure 3. Test-Load Circuit
• POST OFFICE BOX 1443 HOUSTON, TEXAS 77251–1443