SNLS426E – AUGUST 2012 – REVISED JANUARY 2015
7.6 Electrical Characteristics: Serial Management Bus Interface
over recommended operating supply and temperature ranges unless other specified.
PARAMETER
TEST CONDITIONS
SERIAL BUS INTERFACE DC SPECIFICATIONS
VIL
VIH
IPULLUP
Data, Clock Input Low Voltage
Data, Clock Input High Voltage
Current Through Pull-Up Resistor or
Current Source
High Power Specification
VDD
ILEAK-Bus
ILEAK-Pin
CI
RTERM
Nominal Bus Voltage
Input Leakage Per Bus Segment
Input Leakage Per Device Pin
Capacitance for SDA and SCL
External Termination Resistance pull to
VDD = 2.5 V ± 5% or 3.3 V ± 10%
(1)
(1) (2)
Pullup VDD = 3.3 V(1) (2) (3)
Pullup VDD = 2.5 V(1) (2) (3)
(1) Recommended value.
(2) Recommended maximum capacitance load per bus segment is 400 pF.
(3) Maximum termination voltage should be identical to the device supply voltage.
MIN TYP MAX UNIT
0.8 V
2.1
3.6 V
4
mA
2.375
3.6 V
–200
200 µA
–15
µA
10 pF
2000
Ω
1000
Ω
7.7 Timing Requirements
SERIAL BUS INTERFACE TIMING SPECIFICATIONS
FSMB
Bus Operating Frequency(1)
TBUF Bus Free Time Between Stop and Start Condition
THD:STA Hold time after (Repeated) Start Condition. After this
period, the first clock is generated.
TSU:STA Repeated Start Condition Setup Time
TSU:STO Stop Condition Setup Time
THD:DAT Data Hold Time
TSU:DAT Data Setup Time
TLOW
THIGH
tF
tR
tPOR
Clock Low Period
Clock High Period
Clock/Data Fall Time
Clock/Data Rise Time
Time in which a device must be operational after
power-on reset
ENSMB = VDD (Slave Mode)
ENSMB = FLOAT (Master Mode)
At IPULLUP, Max
(2)
(2)
(2) (3)
MIN TYP MAX UNIT
400 kHz
280 400 520 kHz
1.3
µs
0.6
µs
0.6
0.6
0
100
1.3
(2)0.6
µs
µs
ns
ns
µs
50
µs
300 ns
300 ns
500 ms
(1) In Master Mode, a serial EEPROM with a minimum rating of 520 KHz is required.
(2) Compliant to SMBus 2.0 physical layer specification. See System Management Bus (SMBus) Specification Version 2.0, section 3.1.1
SMBus common AC specifications for details.
(3) Specified by Design. Parameter not tested in production.
VOD = [Out+ - Out-]
80%
0V
20%
80%
20%
tRISE
tFALL
Figure 1. CML Output and Rise and FALL Transition Time
Copyright © 2012–2015, Texas Instruments Incorporated
Product Folder Links: DS125BR800
Submit Documentation Feedback