ELECTRICAL CHARACTERISTICS (continued)
Symbol
Parameter
Conditions
Min
VOD1
Output Voltage
Differential Swing
OUT+ and OUT- AC coupled
500
and terminated by 50Ω to GND
VOD_SEL = LOW (700 mV
setting)
DE = LOW
VOD2
Output Voltage
Differential Swing
OUT+ and OUT- AC coupled
800
and terminated by 50Ω to GND
VOD_SEL = FLOAT (1000 mV
setting)
DE = LOW
VOD3
Output Voltage
Differential Swing
OUT+ and OUT- AC coupled
950
and terminated by 50Ω to GND
VOD_SEL = 20K (1200 mV
setting)
DE = LOW
VOD_DE1
De-Emphasis Levels
OUT+ and OUT- AC coupled
and terminated by 50Ω to GND
VOD_SEL = FLOAT (1000 mV
setting)
DE = FLOAT
VOD_DE2
De-Emphasis Levels
OUT+ and OUT- AC coupled
and terminated by 50Ω to GND
VOD_SEL = FLOAT (1000 mV
setting)
DE = 20K
VOD_DE3
De-Emphasis Levels
OUT+ and OUT- AC coupled
and terminated by 50Ω to GND
VOD_SEL = FLOAT (1000 mV
setting)
DE = HIGH
VCM-AC
Output Common-Mode AC Common Mode Voltage
Voltage
DE = 0 dB, VOD <= 1000 mV
VCM-DC
Output DC Common- DC Common Mode Voltage
0
Mode Voltage
VIDLE
TX IDLE Output
Voltage
RLTX-DIFF
TX return loss
SDD22 @ 4.1 GHz
SDD22 @ 11.1 GHz
SCC22 @ 2.5 GHz
delta ZM
TR/F
SCC22 @ 11.1 GHz
Transmitter Termination DC, IFORCE = +/- 100 uA(3)
Mismatch
Transmitter Rise and
Fall Time
20% - 80%(4)
TPD
TCCSK
Propagation Delay
Channel to Channel
Skew
Measured at 50% crossing
T = 25°C, VDD = 2.5V
TPPSK
Part to Part Channel
Skew
T = 25°C, VDD = 2.5V
TDI
Time to transition to
valid electrical IDLE
after an active burst in
OOB signaling
TID
Time to transition to
valid active burst after
leaving electrical IDLE
in OOB signaling
SNLS343C – SEPTEMBER 2011 – REVISED APRIL 2013
Typ
650
Max
800
Units
mVp-p
1000
1100
1150
1350
-3
dB
-6
dB
-9
dB
4.5
mV (RMS)
1.1
1.9
V
30
mV
-13
dB
-9
-22
-10
2.5
%
38
Ω
230
ps
7
ps
20
ps
6.5
ns
3.2
ns
(3) Force +/- 100 uA on output, measure delta V on the Output and calculate impedance. Mismatch is the percentage difference of OUTn+
and OUTn- impedance driving the same logic state.