English
Language : 

MSP430F23X_14 Datasheet, PDF (58/93 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430F23x
MSP430F24x(1)
MSP430F2410
SLAS547I – JUNE 2007 – REVISED DECEMBER 2012
www.ti.com
Comparator_A+ (1)
over recommended operating free-air temperature range (unless otherwise noted)
I(DD)
PARAMETER
TEST CONDITIONS
CAON = 1, CARSEL = 0, CAREF = 0
VCC
2.2 V
3V
I(Refladder/RefDiode)
CAON = 1, CARSEL = 0, CAREF = 1/2/3,
No load at P2.3/CA0/TA1 and P2.4/CA1/TA2
2.2 V
3V
VIC
Common-mode input
voltage range
CAON = 1
2.2 V, 3 V
V(Ref025)
V(Ref050)
V(RefVT)
V(offset)
Vhys
t(response)
Voltage at 0.25 VCC
node / VCC
Voltage at 0.5 VCC node /
VCC
See Figure 36 and
Figure 37
Offset voltage(2)
PCA0 = 1, CARSEL = 1, CAREF = 1,
No load at P2.3/CA0/TA1 and P2.4/CA1/TA2
PCA0 = 1, CARSEL = 1, CAREF = 2,
No load at P2.3/CA0/TA1 and P2.4/CA1/TA2
PCA0 = 1, CARSEL = 1, CAREF = 3,
No load at P2.3/CA0/TA1 and P2.4/CA1/TA2,
TA = 85°C
Input hysteresis
CAON = 1
Response time
(low-to-high and high-to-
low)
TA = 25°C, Overdrive 10 mV,
Without filter: CAF = 0(3)
(see Figure 32 and Figure 33)
TA = 25°C, Overdrive 10 mV,
Without filter: CAF = 1(3)
(see Figure 32 and Figure 33)
2.2 V, 3 V
2.2 V, 3 V
2.2 V
3V
2.2 V, 3 V
2.2 V, 3 V
2.2 V
3V
2.2 V
3V
MIN TYP
25
45
30
45
0
0.23 0.24
0.47 0.48
390 480
400 490
-30
0 0.7
80 165
70 120
1.4 1.9
0.9 1.5
MAX
40
60
50
71
UNIT
µA
µA
VCC - 1 V
0.25
0.5
540
mV
550
30 mV
1.4 mV
300
ns
240
2.8
µs
2.2
(1) The leakage current for the Comparator_A+ terminals is identical to Ilkg(Px.y) specification.
(2) The input offset voltage can be cancelled by using the CAEX bit to invert the Comparator_A+ inputs on successive measurements. The
two successive measurements are then summed together.
(3) The response time is measured at P2.2/CAOUT/TA0/CA4 with an input voltage step, with Comparator_A+ already enabled (CAON = 1).
If CAON is set at the same time, a settling time of up to 300 ns is added to the response time.
58
Submit Documentation Feedback
Copyright © 2007–2012, Texas Instruments Incorporated