POR and Brownout Reset (BOR)(1)(2)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
VCC(start)
V(B_IT-)
Vhys(B_IT-)
td(BOR)
t(reset)
PARAMETER
Operating voltage
Negative going VCC reset threshold voltage
VCC reset threshold hysteresis
BOR reset release delay time
Pulse duration needed at RST/NMI pin to
accepted reset internally
TEST CONDITIONS
dVCC /dt ≤ 3 V/s
dVCC /dt ≤ 3 V/s
dVCC /dt ≤ 3 V/s
VCC
2.2 V, 3 V
MIN TYP MAX UNIT
0.7 × V(B_IT-) V
1.71 V
70 130 210 mV
2000 µs
2
µs
(1) The current consumption of the brownout module is already included in the ICC current consumption data.
The voltage level V(B_IT-) + Vhys(B_IT-) is ≤ 1.8 V.
(2) During power up, the CPU begins code execution following a period of td(BOR) after VCC = V(B_IT-) + Vhys(B_IT-) . The default DCO settings
must not be changed until VCC ≥ VCC(min), where VCC(min) is the minimum supply voltage for the desired operating frequency.
VCC
Vhys(B_IT−)
V(B_IT−)
VCC(s t ar t )
1
0
t d(BOR)
Figure 9. POR/Brownout Reset (BOR) vs Supply Voltage