English
Language : 

MSP430F23X_14 Datasheet, PDF (40/93 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430F23x
MSP430F24x(1)
MSP430F2410
SLAS547I – JUNE 2007 – REVISED DECEMBER 2012
www.ti.com
SVS (Supply Voltage Supervisor and Supply Voltage Monitor)
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP
MAX UNIT
t(SVSR)
td(SVSon)
tsettle
V(SVSstart)
Vhys(SVS_IT-)
dVCC/dt > 30 V/ms (see Figure 12)
dVCC/dt ≤ 30 V/ms
SVSon, switch from VLD = 0 to VLD ≠ 0, VCC = 3 V
VLD ≠ 0(1)
VLD ≠ 0, VCC/dt ≤ 3 V/s (see Figure 12)
VCC/dt ≤ 3 V/s (see Figure 12)
VLD = 1
VLD = 2 to 14
VCC/dt ≤ 3 V/s (see Figure 12), external voltage
applied on A7
VLD = 15
1
150
70
0.001 ×
V(SVS_IT-)
4.4
1.55
120
150
µs
2000
300 µs
12 µs
1.7 V
155 mV
0.016 ×
V(SVS_IT-)
20 mV
V(SVS_IT-)
VLD = 1
VLD = 2
1.8
1.9
2.05
1.94
2.1
2.25
VLD = 3
2.05
2.2
2.37
VLD = 4
2.14
2.3
2.48
VLD = 5
2.24
2.4
2.6
VLD = 6
2.33
2.5
2.71
VCC/dt ≤ 3V/s (see Figure 12 and Figure 13)
VLD = 7
VLD = 8
VLD = 9
2.46 2.65
2.58
2.8
2.69
2.9
2.86
3V
3.13
VLD = 10
2.83 3.05
3.29
VLD = 11
VLD = 12
VLD = 13
VLD = 14
2.94
3.11
3.24
3.43
3.2
3.35
3.5
3.7 (2)
3.42
3.61 (2)
3.76 (2)
3.99 (2)
ICC(SVS) (3)
VCC/dt ≤ 3 V/s (see Figure 12 and Figure 13),
external voltage applied on A7
VLD ≠ 0, VCC = 2.2 V, 3 V
VLD = 15
1.1
1.2
10
1.3
15 µA
(1) tsettle is the settling time that the comparator output needs to have a stable level after VLD is switched from VLD ≠ 0 to a different VLD
value somewhere between 2 and 15. The overdrive is assumed to be > 50 mV.
(2) The recommended operating voltage range is limited to 3.6 V.
(3) The current consumption of the SVS module is not included in the ICC current consumption data.
40
Submit Documentation Feedback
Copyright © 2007–2012, Texas Instruments Incorporated