English
Language : 

BQ33100_15 Datasheet, PDF (52/67 Pages) Texas Instruments – Super Capacitor Manager
bq33100
SLUS987B – JANUARY 2011 – REVISED DECEMBER 2015
8.5.3.4.21 Learning Frequency
Learning Frequency is the amount of time elapsed between automatic learning cycles.
NOTE
A value of 250 is used to set the Learning Frequency to 10 minutes for test purposes.
www.ti.com
Subclass
ID
86
Subclass
Name
Capacitance
Estimation
Offset
18
Table 92. Learning Frequency
Name
Learning
Frequency
Format
Unsigned
Integer
Size in
Bytes
1
Min Value Max Value
0
255
Default
Value
2
Unit
week
8.5.3.4.22 Dsg Current Threshold
The bq33100 enters discharge mode from charge mode if Current < (-) Dsg Current Threshold.
Table 93. Dsg Current Threshold
Subclass
ID
81
Subclass
Name
Current
Thresholds
Offset
0
Name
Dsg Current
Threshold
Format
Integer
Size in
Bytes
Min Value Max Value
Default
Value
Unit
2
0
2000
10
mA
8.5.3.4.23 Chg Current Threshold
The bq33100 enters charge mode from discharge mode if Current > Chg Current Threshold.
Table 94. Chg Current Threshold
SUBCLASS
ID
81
SUBCLASS
NAME
Current
Thresholds
OFFSET
2
NAME
Chg Current
Threshold
FORMAT
Integer
SIZE IN
BYTES
2
MIN
VALUE
0
MAX
VALUE
2000
DEFAULT
VALUE
0
UNIT
mA
8.5.3.4.24 Quit Current
The bq33100 enters relaxation mode from charge mode if Current goes below Quit Current for 60 seconds. The
bq33100 enters relaxation mode from discharge mode if Current goes above (-)Quit Current for 60 seconds.
Table 95. Quit Current
SUBCLASS
ID
81
SUBCLASS
NAME
Current
Thresholds
OFFSET
4
NAME
Quit Current
FORMAT
Integer
SIZE IN
BYTES
2
MIN
VALUE
0
MAX
VALUE
1000
DEFAULT
VALUE
0
UNIT
mA
52
Submit Documentation Feedback
Product Folder Links: bq33100
Copyright © 2011–2015, Texas Instruments Incorporated