English
Language : 

BQ25890H Datasheet, PDF (48/66 Pages) Texas Instruments – I2C Controlled Single Cell 5-A Fast Charger
BQ25890H
SLUSCC5 – SEPTEMBER 2016
www.ti.com
8.4.14 REG0D
Figure 39. REG0D
7
6
5
4
3
2
1
0
0
0
0
1
0
0
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 21. REG0D
Bit
Field
7
FORCE_VINDPM
6
VINDPM[6]
5
VINDPM[5]
4
VINDPM[4]
3
VINDPM[3]
2
VINDPM[2]
1
VINDPM[1]
0
VINDPM[0]
Type
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Reset
by Softwareby
by Softwareby
by Softwareby
by Softwareby
by Softwareby
by Softwareby
by Softwareby
by Softwareby
Description
VINDPM Threshold Setting Method
0 – Run Relative VINDPM Threshold (default)
1 – Run Absolute VINDPM Threshold
Note: Register is reset to default value when input source is plugged-in
6400mV
3200mV
1600mV
800mV
400mV
200mV
100mV
Absolute VINDPM Threshold
Offset: 2.6V
Range: 3.9V (0001101) – 15.3V (1111111)
Default: 4.4V (0010010)
Note:
Value < 0001101 is clamped to 3.9V (0001101)
Register is read only when FORCE_VINDPM=0 and can
be written by internal control based on relative VINDPM
threshold setting
Register can be read/write when FORCE_VINDPM = 1
Note: Register is reset to default value when input source
is plugged-in
8.4.15 REG0E
Figure 40. REG0E
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
R
R
R
R
R
R
R
R
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Bit
Field
7
THERM_STAT
6
BATV[6]
5
BATV[5]
4
BATV[4]
3
BATV[3]
2
BATV[2]
1
BATV[1]
0
BATV[0]
Table 22. REG0E
Type
R
R
R
R
R
R
R
R
Reset
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Description
Thermal Regulation Status
0 – Normal
1 – In Thermal Regulation
1280mV
640mV
320mV
160mV
80mV
ADC conversion of Battery Voltage (VBAT)
Offset: 2.304V
Range: 2.304V (0000000) – 4.848V (1111111)
Default: 2.304V (0000000)
40mV
20mV
48
Submit Documentation Feedback
Product Folder Links: BQ25890H
Copyright © 2016, Texas Instruments Incorporated