THS788
SLOS616B – MARCH 2010 – REVISED JUNE 2011
VCC
R
R
2.5 nH
Bond Wire
IN
0.5 pf
Package
0.1 pf
Bond Pad
0.4 pf
VCC
2.5 nH
Bond Wire
IN
0.5 pf
Package
0.1 pf
Bond Pad
0.4 pf
Figure 9. Simplified Schematic of the LVDS Input
S0389-01
Figure 10 shows the typical input connections. The transmission line lengths must be matched from the driver to
the THS788 input [<0.5 inch (1.27 cm) difference] and terminated in a 100-Ω resistor placed close [<0.25 inch
(0.635 cm)] to the TMU input pins. The resistor total tolerance should be below 5%. The power dissipation is
below 5 mW, so small surface-mounted resistors are preferred.
Copyright © 2010–2011, Texas Instruments Incorporated