English
Language : 

MSP430FR5989-EP Datasheet, PDF (29/154 Pages) Texas Instruments – Mixed-Signal Microcontroller
www.ti.com
MSP430FR5989-EP
SLASEC9 – APRIL 2017
4.13.4 Wake-up Characteristics
Table 4-9 lists the wake-up times.
Table 4-9. Wake-up Times From Low-Power Modes and Reset
over recommended ranges of supply voltage and operating junction temperature (unless otherwise noted)
PARAMETER
TEST
CONDITIONS
VCC
MIN TYP
MAX UNIT
tWAKE-UP FRAM
(Additional) wake-up time to activate the FRAM
in AM if previously disabled by the FRAM
controller or from an LPM if immediate
activation is selected for wakeup
6
10 μs
tWAKE-UP LPM0 Wake-up time from LPM0 to active mode(1)
tWAKE-UP LPM1
tWAKE-UP LPM2
tWAKE-UP LPM3
tWAKE-UP LPM4
tWAKE-UP LPM3.5
Wake-up time from LPM1 to active mode(1)
Wake-up time from LPM2 to active mode(1)
Wake-up time from LPM3 to active mode(1)
Wake-up time from LPM4 to active mode(1)
Wake-up time from LPM3.5 to active mode(2)
tWAKE-UP LPM4.5 Wake-up time from LPM4.5 to active mode(2)
SVSHE = 1
SVSHE = 0
2.2 V, 3.0 V
2.2 V, 3.0 V
2.2 V, 3.0 V
2.2 V, 3.0 V
2.2 V, 3.0 V
2.2 V, 3.0 V
2.2 V, 3.0 V
2.2 V, 3.0 V
400 +
1.5 / fDCO
ns
6
μs
6
μs
7
10 μs
7
10 μs
250
375 μs
250
375 μs
1
1.5 ms
tWAKE-UP-RST
tWAKE-UP-BOR
Wake-up time from a RST pin triggered reset to
active mode(2)
Wake-up time from power-up to active mode (2)
2.2 V, 3.0 V
2.2 V, 3.0 V
318
400 μs
1
1.5 ms
(1) The wake-up time is measured from the edge of an external wake-up signal (for example, port interrupt or wake-up event) to the first
externally observable MCLK clock edge. MCLK is sourced by the DCO and the MCLK divider is set to divide-by-1 (DIVMx = 000b,
fMCLK = fDCO). This time includes the activation of the FRAM during wakeup.
(2) The wake-up time is measured from the edge of an external wake-up signal (for example, port interrupt or wake-up event) until the first
instruction of the user program is executed.
Table 4-10 lists the typical charge consumed during wakeup from various low-power modes.
Table 4-10. Typical Wake-up Charge(1)
also see Figure 4-7 and Figure 4-8
PARAMETER
TEST CONDITIONS MIN TYP MAX UNIT
QWAKE-UP FRAM
Charge used for activating the FRAM in AM or during wake-up
from LPM0 if previously disabled by the FRAM controller.
15.1
nAs
QWAKE-UP LPM0
Charge used for wake-up from LPM0 to active mode (with
FRAM active)
4.4
nAs
QWAKE-UP LPM1
Charge used for wake-up from LPM1 to active mode (with
FRAM active)
15.1
nAs
QWAKE-UP LPM2
Charge used for wake-up from LPM2 to active mode (with
FRAM active)
15.3
nAs
QWAKE-UP LPM3
Charge used for wake-up from LPM3 to active mode (with
FRAM active)
16.5
nAs
QWAKE-UP LPM4
QWAKE-UP LPM3.5
QWAKE-UP LPM4.5
QWAKE-UP-RESET
Charge used for wake-up from LPM4 to active mode (with
FRAM active)
Charge used for wake-up from LPM3.5 to active mode(2)
Charge used for wake-up from LPM4.5 to active mode(2)
Charge used for reset from RST or BOR event to active mode(2)
SVSHE = 1
SVSHE = 0
16.5
nAs
76
nAs
77
nAs
77.5
75
nAs
(1) Charge used during the wake-up time from a given low-power mode to active mode. This does not include the energy required in active
mode (for example, for an interrupt service routine).
(2) Charge required until start of user code. This does not include the energy required to reconfigure the device.
Copyright © 2017, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: MSP430FR5989-EP
Specifications
29