INITIALIZATION OF THE THS10064
The initialization of the THS10064 should be done according to the configuration flow shown in Figure 36.
Start
Use Default
No
Values?
Yes
Write 0x401 to
THS10064
(Set Reset Bit in CR1)
Write 0x401 to
THS10064
(Set Reset Bit in CR1)
Clear RESET By
Writing 0x400 to
CR1
Clear RESET By
Writing 0x400 to
CR1
Write The User
Configuration to
CR0
Write The User
Configuration to
CR1 (Can Include
FIFO Reset, Must
Exclude RESET)
Continue
Figure 36. THS10064 Configuration Flow