English
Language : 

THS10064_09 Datasheet, PDF (17/42 Pages) Texas Instruments – 10-BIT, 4 ANALOG INPUT, 6 MSPS, SIMULTANEOUS SAMPLING ANALOG-TO-DIGITAL CONVERTER
www.ti.com
THS10064
SLAS255B – DECEMBER 1999 – REVISED DECEMBER 2002
Figure 27 shows the timing of continuous conversion mode when one analog input channel is selected. The
maximum throughput rate is 6 MSPS in this mode. The timing of the DATA_AV signal is shown here in the case of
a trigger level set to 1 or 4.
Sample N
Channel 1
Sample N+1 Sample N+2 Sample N+3 Sample N+4 Sample N+5 Sample N+6 Sample N+7 Sample N+8
Channel 1 Channel 1 Channel 1 Channel 1 Channel 1 Channel 1 Channel 1 Channel 1
AIN
tw(CONV_CLKH)
CONV_CLK
Data Into
FIFO
td(A)
td(pipe)
tw(CONV_CLKL)
50%
50%
tc
Data N–5
Channel 1
Data N–4 Data N–3
Channel 1 Channel 1
DATA_AV,
Trigger Level = 1
td(O)
Data N–2 Data N–1
Channel 1 Channel 1
Data N
Channel 1
Data N+1 Data N+2
Channel 1 Channel 1
td(DATA_AV)
Data N+3
Channel 1
td(DATA_AV)
DATA_AV,
Trigger Level = 4
Figure 27. Timing of Continuous Conversion Mode (1-channel operation)
Figure 28 shows the timing of continuous conversion mode when two analog input channels are selected. The
maximum throughput rate per channel is 3 MSPS in this mode. The data flow in the bottom of the figure shows the
order the converted data is written into the FIFO. The timing of the DATA_AV signal shown here is for a trigger level
set to 2 or 4.
Sample N
Channel 1,2
AIN
Sample N+1
Channel 1,2
Sample N+2
Channel 1,2
Sample N+3
Channel 1,2
Sample N+4
Channel 1,2
tw(CONV_CLKH)
CONV_CLK
td(A)
td(Pipe)
tw(CONV_CLKL)
50%
50%
tc
Data Into
FIFO
Data N–3
Channel 2
Data N–2 Data N–2
Channel 1 Channel 2
DATA_AV,
Trigger Level = 2
td(O)
Data N–1 Data N–1
Channel 1 Channel 2
Data N
Channel 1
Data N
Channel 2
Data N+1
Channel 1
Data N+1
Channel 2
td(DATA_AV)
td(DATA_AV)
DATA_AV,
Trigger Level = 4
Figure 28. Timing of Continuous Conversion Mode (2-channel operation)