English
Language : 

THS789 Datasheet, PDF (11/34 Pages) Texas Instruments – THS789 Quad-Channel Time Measurement Unit (TMU)
www.ti.com
THS789
SLOS776A – SEPTEMBER 2012 – REVISED DECEMBER 2015
Table 4. Central Control and Status Registers Description
Register Bit
Name
0 TEST_En
Function
Enables or disables factory test routines.
1 RESET
2 Reserved
3 Reserved
4 Reserved
5 Reserved
6 Reserved
7 Reserved
8 Reserved
9 Reserved
80h
10 OT_En
Reset the device. Device is fully operational after 250 μs.
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Enables or disables the over temperature alarm circuits.
11 RST_OT_ALM Resets the temperature alarm.
12 SYNC_TS_Pol
Defines the polarity of the Sync input for the upcoming
timestamp generation.
13 SYNC_IP_ENI Enables or disables the sync channel
14 PWR_DN
Powers down the device
15 RCLK_En
Enables RCLK
1 Reserved
2 Reserved
81h
3 Quiet_Mod
Reserved
Reserved
It disables the RCLK and digital clks internal during
timestamp process. Allows for only 16 timestamps.
0 TMU_Ready
Indicates that the internal clks, coarse counter and Sync
channel are operational.
1 OT_ALM
82h
Over temperature alarm. Indicates that the junction
temperature is 140°C.
2 DLL_Lock_Sync Indicates the Sync channel DLL lock status.
3 DLL_Lock_1G2 Indicates the lock status of the 1.2-GHz internal clock.
Logic State
0
1
0
1
0
0
0
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
1
1
0
1
0
1
0
1
0
1
0
1
Description
Disabled
Enabled
Reset
Disabled
Enabled
Reset alarm state
Positive edge
Negative edge
Sync disabled
Sync enabled
Powered up
Powered down
Disabled
Enabled
N/A
N/A
Normal mode
Quiet mode
Device is not ready
Device is ready
No alarm
Alarm is enabled
DLL is locked
DLL is not locked
DLL is locked
DLL is not locked
Copyright © 2012–2015, Texas Instruments Incorporated
Product Folder Links: THS789
Submit Documentation Feedback
11