English
Language : 

SMJ44C256 Datasheet, PDF (5/21 Pages) Texas Instruments – 262144 BY 4-BIT DYNAMIC RANDOM-ACCESS MEMORY
SMJ44C256
262144 BY 4-BIT
DYNAMIC RANDOM-ACCESS MEMORY
SGMS034C – MAY 1989 – REVISED JUNE 1995
power up
To achieve proper device operation, an initial pause of 200 µs followed by a minimum of eight initialization
(refresh) cycles is required after power-up to the full VCC level.
test function pin
During normal device operation the TF pin must either be disconnected or biased at a voltage less than or equal
to VCC.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 V to 7 V
Voltage range on any pin (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 1 V to 7 V
Short-circuit output current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 W
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to VSS.
recommended operating conditions
MIN NOM MAX UNIT
VCC
VSS
VIH
VIL
TA
Supply voltage
Supply voltage
High-level input voltage
Low-level input voltage (see Note 2)
Operating free-air temperature
4.5
5 5.5 V
0
V
2.4
6.5 V
–1
0.8 V
– 55
°C
TC
Case temperature
125 °C
NOTE 2: The algebraic convention, where the more negative (less positive) limit is designated as minimum, is used for logic-voltage levels only.
• POST OFFICE BOX 1443 HOUSTON, TEXAS 77251–1443
5