English
Language : 

THS7327 Datasheet, PDF (3/26 Pages) Texas Instruments – 3-Channel RGBHV Video Buffer with I2C Control, Selectable Filters, Monitor Pass-Thru,2:1 Input MUX, and Selectable Input Bias Modes
www.ti.com
THS7327
SLOS502 – SEPTEMBER 2006
DISSIPATION RATINGS
PACKAGE
HTQFP-48 w/PowerPAD (PHP)
θJC
(°C/W)
1.1
θJA
(°C/W)
35
POWER RATING(1)(2)
(TJ = 125°C)
TA = 25°C
TA = 85°C
2.85 W
1.14 W
(1) This data was taken with a PowerPAD standard 3 inch by 3 inch, 4-layer PCB with internal ground plane connections to the PowerPAD.
(2) Power rating is determined with a junction temperature of 125°C. This is the point where distortion starts to substantially increase and
long-term reliability starts to be reduced. Thermal management of the final PCB should strive to keep the junction temperature at or
below 125°C for best performance and reliability.
RECOMMENDED OPERATING CONDITIONS
VSS Supply voltage, VS+
TA
Ambient temperature
MIN NOM MAX UNIT
2.7
5V
–40
85 °C
ELECTRICAL CHARACTERISTICS, VA = VDD = 3.3 V
RL = 150 Ω || 5 pF to GND for Monitor Output, 19 kΩ || 8 pF Load to GND for ADC Buffer, ADC Buffer Filter = 9 MHz, SAG
pin shorted to Monitor Output Pin (unless otherwise noted)
PARAMETER
TEST CONDITIONS
AC PERFORMANCE
Buffer Output
Small-signal bandwidth VO = 0.2 VPP
(–3 dB)
MonitorOutput
Buffer Output
Large-signal bandwidth VO = 1 VPP
(–3 dB)
Slew rate
Monitor Output
Buffer Output
Monitor Output
Buffer Output
Group delay at 100 kHz
Monitor Output
Group delay variation
with respect to 100 kHz
Buffer Output
Attenuation with
respect to 100 kHz
Buffer Output
Filter Select = 9 MHz(1)
Filter Select = 16 MHz(1)
Filter Select = 35 MHz(1)
Filter Select = 75 MHz(1)
Filter Select = Bypass
Filter Select = 9 MHz
Filter Select = 16 MHz
Filter Select = 35 MHz
Filter Select = 75 MHz
Filter Select = Bypass
VO = 2 VPP
Filter Select = Bypass: VO = 1 VPP
VO = 2 VPP
Filter Select = 9 MHz
Filter Select = 16 MHz
Filter Select = 35 MHz
Filter Select = 75 MHz
Filter Select = Bypass
Filter Select = 9 MHz: at 5.1 MHz
Filter Select = 16 MHz: at 11 MHz
Filter Select = 35 MHz: at 27 MHz
Filter Select = 75 MHz: at 54 MHz
Filter Select = 9 MHz: at 5.75 MHz
Filter Select = 9 MHz: at 27 MHz
Filter Select = 16 MHz: at 11 MHz
Filter Select = 16 MHz: at 54 MHz
Filter Select = 35 MHz: at 27 MHz
Filter Select = 35 MHz: at 74 MHz
Filter Select = 75 MHz: at 54 MHz
Filter Select = 75 MHz: at 148 MHz
TYP
25°C
9
16
35
75
500
450
9
16
35
75
500
300
1050
1050
56
31
16
8
1.3
1.3
10.5
7.2
4
2
0.4
39
0.5
40
1
27
0.6
25
25°C
OVER TEMPERATURE
0°C to
70°C
–40°C to
85°C
UNITS
MIN/MAX
7/10.4
13.1/9.6
28/40.5
61/86.8
6.9/10.5
12.9/19.7
27.8/41.3
60.5/90.3
6.8/10.5
12.8/19.7
27.7/41.3
60.4/90.3
-0.3/1.5
31
-0.3/1.5
32
-0.3/2.7
19
-0.3/1.8
17
–0.35/1.55
30.5
–0.35/1.55
31.5
-0.35/2.75
18.5
–0.4/1.9
16.5
–0.4/1.6
30
–0.4/1.6
31
-0.4/2.8
18
–0.45/2
16
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
V/µs
V/µs
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
dB
dB
dB
dB
dB
dB
dB
dB
Min/Max
Min/Max
Min/Max
Min/Max
Typ
Typ
Typ
Typ
Typ
Typ
Typ
Typ
Typ
Typ
Typ
Typ
Typ
Typ
Typ
Typ
Typ
Typ
Typ
Typ
Min/Max
Min
Min/Max
Min
Min/Max
Min
Min/Max
Min
(1) The Min/Max values listed are specified by design only.
Submit Documentation Feedback