English
Language : 

SMD1108 Datasheet, PDF (21/29 Pages) Summit Microelectronics, Inc. – 8-Channel Auto-Monitor ADC In System Programmable Analog (ISPA) Device
SMD1108
Preliminary
Registers 90 through 93 control the sources of activation
for the HEALTHY# and FAULT# outputs. For the
HEALTHY# output to be true all the selected sources must
be within their limits. This is effectively an ANDing
function. For the FAULT# output to be true only one of the
selected sources need be out of limits (ORing). If the
same sources for HEALTHY# and FAULT# are selected
then only one of the two outputs can be true at one time.
7
6
5
4
3
2
1
0 Bit
OV3 OV2 OV1 OV0 UV3 UV2 UV1 UV0
CH7 CH6 CH5 CH4 CH7 CH6 CH5 CH4
Function
0
0
0
0
0
0
0
0 HEALTHY# signal unaffected by condition
1
1
1
1
1
1
1
1 HEALTHY# signal goes false on condition
2052 Table22
Table 22. Register 90 HEALTHY# Deactivation Sources
7
OC3
CH7
0
1
6
OC2
CH6
0
1
5
OC1
CH5
0
1
4
3
2
1
0 Bit
OC0 LIM3 LIM2 LIM1 LIM0
CH4 CH3 CH2 CH1 CH0
Function
0
0
0
0
0 HEALTHY# signal unaffected by condition
1
1
1
1
1 HEALTHY# signal goes false on condition
2052 Table23
Table 23. Register 91 HEALTHY# Deactivation Sources
7
OV3
CH7
0
1
6
OV2
CH6
0
1
5
OV1
CH5
0
1
4
3
2
1
0 Bit
OV0 UV3 UV2 UV1 UV0
CH4 CH7 CH6 CH5 CH4
Function
0
0
0
0
0 FAULT# signal unaffected by condition
1
1
1
1
1 FAULT# signal goes true on condition
2052 Table24
Table 24. Register 92 FAULT# Activation Sources
7
OC3
CH7
0
1
6
OC2
CH6
0
1
5
OC1
CH5
0
1
4
3
2
1
0 Bit
OC0 LIM3 LIM2 LIM1 LIM0
CH4 CH3 CH2 CH1 CH0
Function
0
0
0
0
0 FAULT# signal unaffected by condition
1
1
1
1
1 FAULT# signal goes false on condition
2052 Table25
Table 25. Register 93 FAULT# Activation Sources
SUMMIT MICROELECTRONICS, Inc.
2052 2.0 10/05/01
21