LSM330DL
Registers description
Table 52.
ZD
ZS
YD
YS
XD
XS
CLICK_CFG_A description
Enable interrupt double CLICK on Z-axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
Enable interrupt single CLICK on Z-axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
Enable interrupt double CLICK on Y-axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
Enable interrupt single CLICK on Y-axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
Enable interrupt double CLICK on X-axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
Enable interrupt single CLICK on X-axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
7.19
CLICK_SRC_A (39h)
Table 53. CLICK_SRC_A register
--
IA
DCLICK SCLICK Sign
Z
Y
X
Table 54. CLICK_SRC_A description
IA
Interrupt active. Default value: 0
(0: no interrupt has been generated; 1: one or more interrupts have been generated)
DCLICK Double CLICK-CLICK enable. Default value: 0 (0: double CLICK-CLICK detection dis-
able, 1: double CLICK-CLICK detection enable)
SCLICK Single CLICK-CLICK enable. Default value: 0 (0: single CLICK-CLICK detection disable,
1: single CLICK-CLICK detection enable)
Sign
CLICK-CLICK Sign. 0: positive detection, 1: negative detection
Z
Z CLICK-CLICK detection. Default value: 0 (0: no interrupt, 1: Z high event has occurred)
Y
Y CLICK-CLICK detection. Default value: 0
(0: no interrupt, 1: Y high event has occurred)
X
X CLICK-CLICK detection. Default value: 0
(0: no interrupt, 1: X high event has occurred)
Doc ID 022018 Rev 1