English
Language : 

SI47XX-EVB Datasheet, PDF (59/164 Pages) Silicon Laboratories – Thank you for purchasing the Silicon Laboratories
Si47xx-EVB
uploaded means that the RT is uploaded with the flag set. Un-checking this box when an RT is uploaded
means that the flag is not set. This flag tells the receiver that when the flag toggles from set to reset or vice
versa, the receiver will clear the display before showing the next RT.
5. Manual Group Entry: Use this box to upload the RDS data manually. You can use this box to upload
messages from the Group Type for which the GUI does not have encoding support. For these messages,
the user must encode the messages into hexadecimal code.
6. Circular Buffer Indicator: This displays the message that gets uploaded into the Circular Buffer in
hexadecimal code. This can be useful to see how the Group Type 0 (PS), Type 2 (RT), and Type 4 (CT) is
encoded into RDS data.
7. Delete Circular Buffer Group: This deletes a group that is selected in the Circular Buffer Indicator.
8. FIFO Buffer Indicator: This displays the message that gets uploaded into the FIFO buffer in hexadecimal
code.
9. Delete FIFO Buffer Group: This deletes a group that is selected in the FIFO Buffer Indicator.
Rev. 0.8
59