English
Language : 

SI47XX-EVB Datasheet, PDF (56/164 Pages) Silicon Laboratories – Thank you for purchasing the Silicon Laboratories
Si47xx-EVB
5.10.1. Basic
The RDS Transmit Window is divided into three categories:
1. General
2. Program Service
3. Buffers
In the basic section, we will cover two out of the three categories: the General and Program Service. In the General
category, the user can set the PI and PTY data. In the Program Service, the user can set the PS data (Group Type
0). The following diagram shows a step-by-step explanation:
3
4
1
2
5
Figure 46. Basic RDS Message Illustration
1. First select whether you want to transmit in RDS format (Europe) or RBDS format (US).
2. Type in the Program Identification in this field. Program Identification is a 16-bit code assigned to an
individual station.
3. Select the Program Type in the pull down menu here. Some examples include news, information, sports,
talk, rock, etc.
4. Enter the Program Service (PS) in the boxes provided. You can enter a maximum of 12 different PS
messages, in which each PS message can contain a maximum of 8 characters.
a. Repeat Count: Enter how many times you want each PS message to be transmitted before sending
the next PS message.
b. Message Count: Enter how many of the 12 PS messages that you actually want to transmit.
c. Mix: Select 100 percent.
5. Click Send Message button here. Now the RDS will transmit the PS message along with the PI and PTY.
You should see these data in your RDS receiver.
56
Rev. 0.8