English
Language : 

SI47XX-EVB Datasheet, PDF (107/164 Pages) Silicon Laboratories – Thank you for purchasing the Silicon Laboratories
Si47xx-EVB
8.6. AM Receiver Logging Tools Info
8.6.1. Log Band Scan
Selecting ToolsLog Band Scan allows you to specify a filename and begin a scan of the entire band. The scan
feature starts with the first frequency in the band and then seeks to the first station that meets the seek criteria
(Seek RSSI Threshold, Seek SNR Threshold). When a valid station is found, the software waits at the station and
logs Frequency, AFC, RSSI, SNR, Soft Mute etc settings and then seeks to the next valid station. While scanning,
the software displays a green "Scanning" notice below the menu bar. The scan can be aborted by selecting the
ToolsLog Band Scan a second time. When the scan completes, the filename given is saved in comma separated
format and is available for analysis in a text editor or spreadsheet.
8.6.2. Log Device Commands
Selecting ToolsLog Device Commands prompts for a filename in which all software API calls and data with
timestamp data will be logged as text. The logging will continue until ToolsLog Device Commands is selected a
second time, at which point the file is saved and available for analysis in a text editor.
8.6.3. Log Channel Info
Selecting ToolsLog Channel Info prompts for a filename in which all register values will be logged in comma
separated format. The software then logs all register values and the time at which it was received. The logging will
continue until ToolsLog Channel Info is selected a second time, at which point the file is saved and available for
analysis in a text editor or spreadsheet.
Rev. 0.8
107