3.3. Hardware Setup for AM Receiver Test
Audio
Analyzer
RCA Cable
J28 or J26
J24 FMIN
RF
Generator
SMA Cable
Si473x
J1 Daughterboard
J6
RCA OUT
J7
RCA IN
J19
Optical
Cable
Jumpers
Setting
DCLK
TX
TX
GPIO3
RX
RX
J41
J44 J45
Note: J44 and J45 are
automatically configured in
EVB Rev1.3 and later
S/PDIF
OUT
J30
Si47xx
Baseboard
J76
USB
SW1
EXT pwr
Terminal
Block (TB)
J79
USB pwr
USB Cable
J78
EXT Jack
PC
w/ USB
port
Figure 21. Hardware Setup for AM Receiver Test (Si473x)
Instructions for Si473x daughtercards.
1. Connect the USB cable from PC to the EVB USB connector, J79. The USB connection will not only allow controlling of the
EVB, but will also provide power to the EVB.
2. Connect either the ferrite antenna or the airloop antenna board. The user also has the option of using the AM test input for
characterization by connecting the AM test input connector J1 to an RF generator source.
3. Connect an audio analyzer to the RCA output (connector J6) using an RCA cable for the analog audio output.
4. Connect an audio analyzer to the S/PDIF output (connector J30) using an optical cable.
5. Or, connect the headphone output to J24 on the daughtercard.
6. J19 and J30 S/PDIF connections are no longer supported on EVBs as of February 14, 2011.
30