English
Language : 

C8051F340-GQR Datasheet, PDF (26/276 Pages) Silicon Laboratories – Full Speed USB Flash MCU Family
C8051F340/1/2/3/4/5/6/7/8/9/A/B/C/D
Table 3.1. Global DC Electrical Characteristics (Continued)
–40 to +85 °C, 25 MHz System Clock unless otherwise specified.
Parameter
Conditions
Min Typ Max
IDD Frequency Sensitivity3,6 VDD = 3.3 V, SYSCLK < 1 MHz, 
0.44
T = 25 ºC
VDD = 3.3 V, SYSCLK > 1 MHz, 
0.32
T = 25 ºC
Units
mA/MHz
mA/MHz
VDD = 3.6 V, SYSCLK < 1 MHz, 
T = 25 ºC
VDD = 3.6 V, SYSCLK > 1 MHz, 
T = 25 ºC
0.49
mA/MHz
0.36
mA/MHz
Digital Supply Current (Stop
Mode, shutdown)
Oscillator not running, 
VDD monitor disabled
< 0.1
µA
Digital Supply Current for USB VDD = 3.3 V, USB Clock = 48 MHz
8.69
mA
Module (USB Active Mode)
VDD = 3.6 V, USB Clock = 48 MHz
9.59
mA
Digital Supply Current for USB Oscillator not running
Module (USB Suspend Mode) VDD monitor disabled
< 0.1
µA
Notes:
1. USB Requires 3.0 V Minimum Supply Voltage.
2. SYSCLK must be at least 32 kHz to enable debugging.
3. Based on device characterization of data; Not production tested.
4. Active and Inactive IDD at voltages and frequencies other than those specified can be calculated using the IDD
Supply Sensitivity. For example, if the VDD is 3.0 V instead of 3.3 V at 24 MHz: IDD = 13.9 mA typical at 3.3 V
and SYSCLK = 24 MHz. From this, IDD = 13.9 mA + 0.46 x (3.0 V – 3.3 V) = 13.76 mA at 3.0 V and SYSCLK
= 24 MHz.
5. IDD can be estimated for frequencies < 30 MHz by multiplying the frequency of interest by the frequency
sensitivity number for that range. When using these numbers to estimate IDD for > 30 MHz, the estimate should
be the current at 24 MHz (or 48 MHz) minus the difference in current indicated by the frequency sensitivity
number. For example: VDD = 3.3 V; SYSCLK = 35 MHz, IDD = 13.9 mA – (24 MHz – 35 MHz) x 0.44 mA/MHz =
18.74 mA.
6. Idle IDD can be estimated for frequencies < 1 MHz by multiplying the frequency of interest by the frequency
sensitivity number for that range. When using these numbers to estimate Idle IDD for > 1 MHz, the estimate
should be the current at 24 MHz (or 48 MHz) minus the difference in current indicated by the frequency
sensitivity number. For example: VDD = 3.3 V; SYSCLK = 5 MHz, Idle IDD = 8.25 mA – (24 MHz – 5 MHz) x
0.32 mA/MHz = 2.17 mA.
Other electrical characteristics tables are found in the data sheet section corresponding to the associated
peripherals. For more information on electrical characteristics for a specific peripheral, refer to the page
indicated in Table 3.2.
26
Rev. 1.3