English
Language : 

S-7600A Datasheet, PDF (10/60 Pages) Seiko Instruments Inc – Hardware Specification (TCP/IP Network Stack LSI)
TCP/IP Network Stack LSI
S-7600A
Hardware Specification Revision 1.3
1.4. Trademarks
iReady iAPITM and iAPITM is a trademark of iReady Corporation. All other products and brand names are
trademarks and registered trademarks of their respective companies.
1.5. Definitions
z IP
z PPP
z TCP
z UDP
z API
Internet Protocol
Point-to-Point Protocol
Transmission Control Protocol
User Datagram Protocol
Application Programming Interface
1.6. Applicable Documents
z S-7600A Functional Specification
z S-7600A API Application Manual
1.7. Cautions
1. DO NOT apply a voltage or current that exceeds the absolute maximum ratings to terminals. If
applied, the IC may malfunction or be destroyed.
The standard values are set with sufficient margins, but use the IC within the recommended
operating conditions to optimize device quality.
2. Measures against static electricity
2.1 When transporting or storing ICs, use conductive containers or metal coated boxes.
2.2 Check that there is no current leakage in electrical facilities, and be sure to ground them.
Also ensure that workbenches and people who handle ICs are grounded.
3. Excessive external noise to the power supply or I/O terminals of CMOS ICs causes latch-up, leading
to faults and damage. If latch-up has occurred, immediately turn off the device, eliminate the cause,
and turn on the device again.
4. Keep the IC away from mechanical vibration, shock, and sudden changes in temperature. These
may cause wires to break.
5. Environment
5.1 Use and store ICs below the absolute maximum rated temperature.
5.2 DO NOT use or store ICs where condensation can occur.
5.3 DO NOT use ICs where they are directly exposed to dust, salt, or acid gas such as SO2.
These may cause leaks between element leads and cause corrosion.
5.4 To store ICs for a long time, DO NOT process them. During storage, DO NOT apply any load
to ICs.
1-2
Seiko Instruments Inc.