CH1LOSHYS = 0
CH1LOSHYS = 9
CH1LOSHYS = 15
70
60
50
40
30
20
10
0
0
50
100
150
200
250
300
CH1LOSTHNEG
Figure 3-14: Ch1 LOS Threshold vs. Hysteresis (CH1LOSRANGE = 2)
CH1LOSHYS = 0
CH1LOSHYS = 9
CH1LOSHYS = 15
35
30
25
20
15
10
5
0
0
50
100
150
200
250
300
CH1LOSTHNEG
Figure 3-15: Ch1 LOS Threshold vs. Hysteresis (CH1LOSRANGE = 3)
3.5.2.2 Ch1 LOS Hysteresis
The LOS detector supports programmable hysteresis ranging from 0dB to 6dB,
adjustable in steps of less than 0.5dB. The following register can be used to program the
hysteresis. Note that the effective hysteresis is somewhat dependent on the threshold
value:
Register Name
CH1_REG13
Register
Addressd
60
Parameter Name
CH1LOSHYS
Bit
Position
Access
3:0
RW
Reset Valueb
1001
Valid
Ranged
Function
0-15
Sets LOS hysteresis from 0dB to 6dB in steps
of 0.5dB.