Section 5 Differences between the MCUs and the Emulator
• Program Flash
This mode is used when the emulator is used for programming the flash memory.
Debugging the program is disabled. To download the load module, register it in the
workspace.
Note: In the H8/Tiny or H8/Super Low Power device, the ID code is not entered in the Program
Flash mode.
⎯ Power Supply
When [Power Target from emulator. (MAX 300mA)] is checked, power will be supplied to
the user system up to 300 mA. Then select 3.3 V or 5.0 V according to the power voltage
of the user system.
3. Emulator Activation and ID Code
In the H8/Tiny- or H8/Super Low Power-series MCU, the [System Clock] and [ID Code]
dialog boxes are set when the emulator is activated.
⎯ Setting the system clock
Enter the clock value input to the board in use. The initial value differs in each MCU.
Figure 5.2 [System Clock] Dialog Box
⎯ Setting the ID code
When the emulator is activated in the [Erase Flash and Connect] mode, enter any
hexadecimal four-digit ID code to be set (except for H'FFFF). The initial value is H’0E8A.
When the emulator is activated in the [Keep Flash and Connect] mode, enter the correct ID
code. If an incorrect ID code is entered, all the contents of the flash memory will be erased.
In this case, restart the emulator in the [Erase Flash and Connect] mode.
Rev. 1.00 Aug.03, 2009 Page 15 of 22