English
Language : 

AR0135CS Datasheet, PDF (22/27 Pages) ON Semiconductor – 1/3‐inch 1.2 Mp CMOS Digital Image Sensor
AR0135CS
Power-Down Sequence
The recommended power-down sequence for the
AR0135CS is shown in Figure 20. The available power
supplies (VDD_IO, VDD, VDD_SLVS, VDD_PLL, VAA,
VAA_PIX) must have the separation specified below.
1. Disable streaming if output is active by setting
standby R0x301A[2] = 0
2. The soft standby state is reached after the current
row or frame, depending on configuration, has
ended.
3. Turn off VDD_SLVS.
4. Turn off VDD.
5. Turn off VDD_IO
6. Turn off VAA/VAA_PIX.
7. Turn off VDD_PLL.
VDD_SLVS (0.4)
VDD (1.8)
VDD_IO (1.8/2.8)
VAA_PIX
VAA (2.8)
VDD_PLL (2.8)
EXTCLK
t0
t1
t2
t3
t4
Power Down until Next
Power Up Cycle
Figure 20. Power Down
Table 19. POWER-DOWN SEQUENCE
Symbol
Parameter
Min
Typ
Max
Unit
t0
VDD_SLVS to VDD
0
–
–
ms
t1
VDD to VDD_IO
0
–
–
ms
t2
VDD_IO to VAA/VAA_PIX
0
–
–
ms
t3
VAA/VAA_PIX to VDD_PLL
0
–
–
ms
t4
PwrDn until Next PwrUp Time
100
–
–
ms
1. t4 is required between power down and next power up time; all decoupling caps from regulators must be completely discharged.
www.onsemi.com