English
Language : 

E32DC200E Datasheet, PDF (7/56 Pages) Omron Electronics LLC – 530 Watts ECL Series
ì¡í²ÅEÉAÉvÉäÉPÅ[ÉVÉáÉì
Standard Models
Fluorine Coating
U
• Fiber degradation due to oil is prevented using a fluo- ■ Feature: Fluorine Coating
roresin coating.
• Free cutting is possible with cutter provided.
(Cross section)
Oil is blocked!
Fluororesin coating
Fluororesin is used as the sheath material to prevent fi-
ber degradation resulting from oil adhesion.
Note: The tip of the head is not chemical-resistant.
■ Ratings/Characteristics
Min. sensing
object
0.005-mm dia.
Min. bending
radius
4 mm
Ambient tem-
perature range
−40°C to 70°C (with no icing or condensation)
Fiber material Plastic
Fiber Customization Service
(Fiber Length, Sleeve
Length, and Bends)
Fiber Length
■Aplicable Models
Standard models
■Model Number Used for Ordering
Standard model number + Fiber length
Fiber length: 0.3 m, 0.5 m, or any length from
1 to 20 m (in 1-m units)
Sleeve Length and Bends
■Applicable Models
E32-TC200B/E32-TC200F
E32-DC200B/E32-DC200F
The E32-DC200B cannot be bent.
This customization/delivery service applies to standard models. It is
aimed at reducing industrial waste and simplifying the installation
procedure.
■ Fiber Length vs. Sensing Distance
Through-beam Fiber Units
Fiber Units with Reflective Sensors
(Fiber length of 2 m corresponds to (Fiber length of 2 m corresponds to
100%.)
100%.)
100
100
80
80
60
60
40
40
20
20
0 25
10
15
20
Fiber length (m)
02 5
10
15
20
Fiber length (m)
■ Model Number Used When Changing Only the Sleeve Length
L
Model: E32- *1 C200 *2 -S *3
■ Model Number Used When Changing the Sleeve Length and Bends
Total length
Total length
L1
R
L2
R
Model Numbers Incorporating the Bending Radius, R, and Dimensions L1 and L2
Specifying L1 Only
(Units: mm) Specifying L2 Only
(Units: mm)
Bending
radius
L1 (±1)
Model number
Bending
radius
L2 (±1)
Model number
R5
10 E32- *1 C200 *2 -S *3 A1 R5
5
E32- *1 C200 *2 -S *3 A3
15 E32- *1 C200 *2 -S *3 A2
10 E32- *1 C200 *2 -S *3 A4
R7.5 12.5 E32- *1 C200 *2 -S *3 B1 R7.5 7.5 E32- *1 C200 *2 -S *3 B3
17.5 E32- *1 C200 *2 -S *3 B2
17.5 E32- *1 C200 *2 -S *3 B4
R10 15 E32- *1 C200 *2 -S *3 C1 R10 10 E32- *1 C200 *2 -S *3 C3
20 E32- *1 C200 *2 -S *3 C2
20 E32- *1 C200 *2 -S *3 C4
R12.5 17.5 E32- *1 C200 *2 -S *3 D1 R12.5 12.5 E32- *1 C200 *2 -S *3 D3
22.5 E32- *1 C200 *2 -S *3 D2
22.5 E32- *1 C200 *2 -S *3 D4
*1: Insert "T" for Through-beam Fiber Units and "D" for Fiber Units with Reflective Sensors.
*2: Insert the "B" or "F" that appears at the end of the original model number.
*3: Insert "50" if the total length is 50 mm. The total length must not exceed 120 mm.
7