English
Language : 

E32DC200E Datasheet, PDF (35/56 Pages) Omron Electronics LLC – 530 Watts ECL Series
Fiber Units
Type
Item
E32-T5@
E32-D5@
Ambient operating
temperature range *1
−40°C to 150°C *4
Ambient humidity
range *1
35% to 85%
Fiber material
Plastic
(fluororesin coating)
Degree of protection IEC standard: IP67
Environment-resistive models
E32-T8@R-S
E32-D8@R-S
Heat-resistant
E32-T84S-S
E32-T6@-S
E32-D6@-S
−40°C to 200°C *3
−60°C to 350°C *3
Glass
(fluororesin coating)
Glass (SUS spiral coating)
E32-D73-S
−40°C to 400°C *3
Type
Environment-resistive models
Item
Chemical-resistant
Vacuum-resistant
All other models
Ambient operating
temperature range *1
−40°C to 70°C
Ambient humidity
range *1
35% to 85%
E32-T51F
−40°C to 150°C *4
Fiber material
Plastic (fluororesin coating)
Degree of protection IEC standard: IP67
E32-T81F-S
−40°C to 200°C *3
All other models
−25°C to 120°C
32-T84SV
−25°C to 200°C
Glass
(fluororesin coating)
Glass
(fluororesin coating)
---
Glass
(SUS spiral coating)
Type
Application-corresponding models
Item
Label-detection
All other models
Ambient operating
temperature range *1
−40°C to 70°C
Ambient humidity
range *1
35% to 85%
Fiber material
Plastic (polyethylene coating)
Liquid-level detection
E32-A01
E32-A02
E32-D82F
−40°C to 200°C *3
Wafer-mapping
−40°C to 70°C
Plastic
(fluororesin coating)
(Fluororesin coating)
Plastic
(polyethylene coating)
Degree of protection IEC standard: IP67 IEC standard: IP50
IEC standard: IP68 IEC standard: IP50
Other
Repeat accuracy: 1 mm max.
Repeat accuracy:
0.5 mm max.
Type
Application-corresponding models
Item
Glass-substrate-alignment
Glass-substrate-mapping
All other models
E32-L66
Ambient operating
temperature range *1
−40°C to 70°C
0°C to 300°C *3, *5
Ambient humidity
range *1
35% to 85%
Fiber material
Plastic
Glass
(polyethylene coating) (SUS spiral coating)
Degree of protection IEC standard: IP40
E32-A09
−40°C to 70°C
E32-A09H
−40°C to 150°C *4
Plastic
Plastic
(polyethylene coating) (fluororesin coating)
E32-A09H2
−40°C to 300°C *3
Glass
(SUS spiral coating)
*1. There must be no icing or condensation within the range specified for the ambient operating temperature.
*2. For continuous operation, use the products within a temperature range of −40°C to 90°C.
*3. The maximum temperature that can be withstood varies with the location. Refer to dimensions diagrams for details.
*4. For continuous operation, use the products within a temperature range of −40°C to 130°C.
*5. These values are based on the assumption that there are no repeated sudden changes in temperature.
35