English
Language : 

E32DC200E Datasheet, PDF (29/56 Pages) Omron Electronics LLC – 530 Watts ECL Series
Fiber Units with Reflective Sensors
High-resolution mode
Standard mode
(
High-speed mode
*When used in combination with the E3X-DA-S Amplifier Unit (general-purpose).
Super-high-speed mode)
Type
Appearance (mm) *3
Sensing distance (mm) *1
3.3
3.3
3.3 (3.3)
(Min. sensing
object) (mm) *2
Min.
bending
radius
(mm)
R25
Features Model number
Small level dif-
ferences, high E32-L25
power, side-view
Small level dif-
ferences, top-
view
E32-L25A
0 to 4
0 to 4
0 to 4 (0 to 4)
2 to 6 (center: 4)
2 to 6 (center: 4)
2 to 6 (2 to 6) (center: 4)
5.4 to 9 (center: 7.2)
5.4 to 9 (center: 7.2)
5.4 to 9 (5.4 to 9) (center: 7.2)
4 to 10
4 to 10
4 to 10 (4 to 10)
0 to 15
0 to 15
0 to 12 (0 to 12)
(0.005 dia.)
Ultracompact,
flat-view
E32-L24S
Heat resistant
R10 up to 105°C *4, E32-L24L
top-view
Heat resistant
up to 105°C *4, E32-L25L
top-view
Heat resistant
up to 200°C, flat- E32-L86
view
R25
Wide-range
sensing, flat- E32-L16
view
150°C*5
400
230
M6
160 (72)
R35
Heat resistant
up to 150°C
E32-D51
200°C*6
350°C*6
M6
150
90
60 (27)
M6
400°C*6
M4 1.25 dia.
Min. bending radius
of sleeve: 10
6 dia.
100
60
40 (18)
160
95
65 (30)
70
7 dia.
40
30 (10)
(0.005 dia.)
(0.005 dia.)
R10
Heat resistant
up to 200°C
E32-D81R-S
E32-D81R
Heat resistant E32-D61-S
up to 350°C
E32-D61
R25
Heat resistant
up to 400°C,
with sleeve
E32-D73-S
E32-D73
Fluororesin cov-
er, long distance
E32-D12F
R40
Fluororesin cov-
er, side-view
E32-D14F
*1. The sensing distances are for white paper.
*2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set
to optimum values.
*3.
Indicates models that allow free cutting.
*4. For continuous operation, use the products within a temperature range of −40°C to 90°C.
*5. For continuous operation, use the products within a temperature range of −40°C to 130°C.
*6. The maximum temperature that can be withstood varies with the location. Refer to dimensions diagrams for details.
*7. Confirm applicable Amplifier Units before placing an order. (Refer to Precautions for Correct Use.)
29