E32DC200E Datasheet, PDF (40/56 Pages) Omron Electronics LLC – 530 Watts ECL Series
Through-beam Fiber Units
Heat-resistant Models
E32-T81R-S
M2.6 × 0.45
Two hexagonal nuts
Two toothed washers
Sensing head:
M4 × 0.7 *1
Protective tube
3.6 dia. 2 dia. Fluororesin tube
4 dia.
Sleeve 2.2 dia.
0.7 dia.
7
(75)
3
2.4 4 dia.
20
10
A
2,000
5
13 *2
25
B
Indicates models that allow free cutting.
*1. Material: Stainless steel (SUS303)
Note: The maximum allowable temperatures for sec-
tions A and B are 200°C and 110°C, respective-
ly. The section inserted into the Amplifier Unit
(indicated by *2), however, must stay within the
Amplifier Unit's operating temperature range.
E32-T84S-S
A
(14.2)
12
2,000
5
B
25
13 *2
E32-T61-S
1 dia.
Two hexagonal nuts Flexible tube: 2.8 dia. (stainless steel)
Two toothed washers
Hexagonal caulking
M2.6 × 0.45
Sensing head:
M4 × 0.7 *1
4 dia. Sleeve 2.2 dia.
30 max. 6
12
R5 3 dia.
90°
3.5 dia.
4 dia.
Flexible tube:
2.9 dia.
(stainless steel)
4 dia.
2.2 dia.
Sleeve
Antislip tread
*1. Material: Stainless steel (SUS303)
Sensing head *1
3 dia.
Note: The maximum allowable temperatures
for sections A and B are 200°C and
110°C, respectively. The section inserted
Lens (2 dia.)
into the Amplifier Unit (indicated by *2),
however, must stay within the Amplifier
Unit's operating temperature range.
7
3
20 2.4
4 dia. *3
10
A
5
2,000
13 *2
25
B
*1. Material: Stainless steel (SUS303)
*3. The diameter is 6 mm if the fiber
length exceeds 10 m.
Note: The maximum allowable temperatures for sections A and B are 200°C
and 110°C, respectively. The section inserted into the Amplifier Unit (in-
dicated by *2), however, must stay within the Amplifier Unit's operating
temperature range.
Chemical-resistant Models
E32-T11F
Lens: 3 dia.
Sensing head *1 Nut *1
10
7.2 dia.
E32-T12F
Optical fiber: 2.2 dia. *2
Lens: 4 dia. Sensing head: 5 dia. Fluororesin
(10.7)
R3.6
19.8
10
3
(35)
2,000
20
*1. Material: PFA
*2. Sheath material: Fluororesin
2,000
4 dia. Optical fiber: 2.2 dia.
100
E32-T14F
Sensing head: 5 dia. Fluororesin
4 dia.
4.5
Optical
axis
(21)
2,000
E32-T51F
Optical fiber: 2.2 dia.
2,000
100
(20)
Lens: 3.7 dia.
Fluororesin Optical fiber: 2.2 dia.
100
Sensing head: 5 dia.
E32-T81F-S
6 dia.
(R6)
PFA cover
3.7 dia.
(0.8)
30
Protective tube
PFA tube
2 dia.
(70)
2,000
5
A
4 dia. Sleeve 2.2 dia.
13 *2
25
B
Note: The maximum allowable temperatures for sec-
tions A and B are 200°C and 110°C, respective-
ly. The section inserted into the Amplifier Unit
(indicated by *2), however, must stay within the
Amplifier Unit's operating temperature range.
40