English
Language : 

E32DC200E Datasheet, PDF (23/56 Pages) Omron Electronics LLC – 530 Watts ECL Series
Through-beam Fiber Units
Type
Appearance (mm) *2
Sensing distance (mm)
Standard object Min.
(min. sensing
bending
radius
object) (mm)*1 (mm)
Features
Model number
30
10
M3
150°C*5
M4
2 dia.
M4
200°C*6
M4
M4
3 dia.
350°C*6
M4
1,700
1,300
850 (340)
(0.3 dia.) *3
2,300
1,800
1,150 (450)
R
R1 Area width:
30 mm
R10
E32-T16WR
E32-T16W
3,700
2,800
(0.6 dia.) *4
1,850 (740)
Area width:
10 mm; long dis- E32-T16
tance
R25
750
610
350 (140)
2 dia. (0.1 dia)
Multi-point detec-
tion (4-head)
E32-M21
1,000
760
500 (200)
300
230
150 (60)
1.5 dia.
(0.1 dia.)
Heat-resistant up
to 150°C
E32-T51
R35
Heat-resistant up
to 150°C; side- E32-T54
view
360
280
180 (70)
1 dia.
(0.005 dia.)
R10
Heat-resistant up
to 200°C
E32-T81R-S
600
450
300 (120)
3 dia. (0.1 dia.)
Heat-resistant up
to 200°C; side-
view
E32-T61-S+
E39-F2
4,000*7
3,400
4 dia. (0.1 dia.)
2,200 (900)
Heat-resistant up
to 200°C, long
distance
E32-T61-S+
E39-F1
R25 Heat-resistant up
1,750
1.7 dia.
1,300
870 (350)
(0.1 dia)
to 200°C; L-
shaped; long dis-
E32-T84S-S
tance
600
450
300 (120)
1 dia.
(0.005 dia.)
Heat-resistant up
to 350°C
E32-T61-S
7.2 dia.
5 dia.
2,500
2,000
1,300 (520)
R4
Fluororesin cover,
round head
E32-T11F
4 dia. (0.1 dia.)
4,000*7
3,000
2,000 (800)
Fluororesin cover,
long distance
E32-T12F
5 dia.
500
400
250 (100)
3 dia. (0.1 dia.)
R40
Fluororesin cover,
side-view
E32-T14F
1,800
Fluororesin cover,
1,400 4 dia. (0.1 dia.)
heat-resistant up E32-T51F
5 dia.
900 (350)
to 150°C *5
6 dia.
920
700
460 (190)
1 dia.
(0.005 dia.)
Fluororesin cover,
R10 heat-resistant up E32-T81F-S
to 200°C *6
*1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set
to optimum values.
*2.
Indicates models that allow free cutting.
*3. This is the value for which detection is possible within the sensing area, with the sensing distance set to 300 mm. (The sensing object is stationary.)
*4. This is the value for which detection is possible within the sensing area, with the sensing distance set to give a digital value of 1,000. (The sensing object is sta-
tionary.)
*5. For continuous operation, use the products within a temperature range of−40°C to 130°C.
*6. The maximum temperature that can be withstood varies with the location. Refer to dimensions diagrams for details.
*7. The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
23