English
Language : 

PIC24F04KA201 Datasheet, PDF (201/224 Pages) Microchip Technology – 14/20-Pin General Purpose, 16-Bit Flash Microcontrollers with nanoWatt XLP™ Technology
PIC24F04KA201 FAMILY
TABLE 26-20: PLL CLOCK TIMING SPECIFICATIONS (VDD = 1.8V TO 3.6V)
AC CHARACTERISTICS
Standard Operating Conditions: 1.8V to 3.6V (unless otherwise stated)
Operating temperature -40°C ≤ TA ≤ +85°C for Industrial
Param
No.
Sym
Characteristic(1)
Min
Typ(2)
Max Units
Conditions
OS50 FPLLI PLL Input Frequency
Range
4
—
8
MHz ECPLL, HSPLL modes
OS51 FSYS PLL Output Frequency
16
—
32
MHz
Range
OS52 TLOCK PLL Start-up Time
(Lock Time)
—
—
2
ms
OS53 DCLK CLKO Stability (Jitter)
-2
1
2
% Measured over 100 ms period
Note 1: These parameters are characterized but not tested in manufacturing.
2: Data in “Typ” column is at 3.3V, 25°C unless otherwise stated. Parameters are for design guidance only
and are not tested.
TABLE 26-21: AC CHARACTERISTICS: INTERNAL RC ACCURACY
AC CHARACTERISTICS
Standard Operating Conditions: 1.8V to 3.6V (unless otherwise stated)
Operating temperature -40°C ≤ TA ≤ +85°C for Industrial
Param
No.
Characteristic
Min Typ Max Units
Conditions
Internal FRC Accuracy @ 8 MHz(1)
F20
FRC
-2
—
2
%
+25°C
3.0V ≤ VDD ≤ 3.6V
-5
—
5
% -40°C ≤ TA ≤ +85°C
Note 1: Frequency calibrated at 25°C and 3.3V. OSCTUN bits can be used to compensate for temperature drift.
TABLE 26-22: AC CHARACTERISTICS: INTERNAL RC ACCURACY
AC CHARACTERISTICS
Standard Operating Conditions: 1.8V to 3.6V (unless otherwise stated)
Operating temperature -40°C ≤ TA ≤ +85°C for Industrial
Param
No.
Characteristic
Min Typ Max Units
Conditions
LPRC @ 31 kHz(1)
F21
Note 1:
-15
—
15
-15
—
15
Change of LPRC frequency as VDD changes.
%
+25°C
3.0V ≤ VDD ≤ 3.6V
% -40°C ≤ TA ≤ +85°C
© 2009 Microchip Technology Inc.
Preliminary
DS39937B-page 199