English
Language : 

801-2-31-A40 Datasheet, PDF (25/28 Pages) Magnetrol International, Inc. – KotronTM II Series 801 RF Capacitance Transmitter For Level/Flow/Volume
TROUBLESHOOTING cont.
SYMPTOM
CCO/PROBE
(1) or (2) FAIL
Various
PROBLEM
NO CLOCK PRESENT
The real time clock was not found on the board.
No data logging or time sampling is allowed.
LOOP > 20 mA
The calculated value for the loop output is
greater than 20 mA. The loop output will be in
its fail-safe mode.
LOOP < 4 mA
The calculated value for the loop output is less
than 4 mA. The loop output will be in its
fail-safe mode.
DISPLAY IS TOO
DIM OR TOO LIGHT
SOLUTION
Consult Extended Errors section on page 23 of
this manual.
If you need the real time functions, contact
the factory to determine if your unit was ordered
with the data logging option.
If the level is within a normal operating
range, adjust the loop parameters to allow
proper tracking of the level. If the level is out of
the normal 4–20 mA range, then correct the
problem with the level.
If the level is within a normal operating
range, adjust the loop parameters to allow
proper tracking of the level. If the level is out of
the normal 4–20 mA range, then correct the
problem with the level.
Turn R11(contrast adjustment) clockwise to
darken the display or counterclockwise to lighten
the display until the desired contrast is obtained.
SPECIFICATIONS
ELECTRICAL SPECIFICATIONS
Description
Supply Voltage
Analog
Output
Digital
Range
Accuracy
Repeatability
Linearity
Data
Entry
Indication
AC
Relays
4 SPDT
DC
Set Point
Range
Differential
Range
Time Delay
Specification
120 VAC, 50-60 Hz
240 VAC, 50-60 Hz
24 VDC
4–20 mA (Isolated), reversible
1000 ohms max. loop resistance
RS-232
5 pF minimum
50,000 pF maximum
Better than 1.0% of span
± .1%
± .5%
Full numeric keypad
16 character alphanumeric
LCD display
10A @ 120/240 VAC resistive
10A @ 30 VDC resistive
0.5A @ 125 VDC resistive
0-50,000 pF
0.50 pF minimum,
50,000 pF maximum
0-120 Seconds
Level Rising, Falling, Both
Description
Power Consumption
Humidity
Operating Pressure
and Temperature
Electrostatic Discharge
Protection
Response Time
Ambient Temperature
(Electronics)
Temperature Coefficient
of Set Point
-20° F to +160° F
(-29° C to +71° C)
Maximum Remote
Mount Distance
Specification
15 VA maximum
99% Non-condensing (electronics)
Dependent upon probe selection
See Bulletin 50-125.
Per IEC specification 801-2.
0.5 to approx. 2 seconds,
depending upon probe
capacitance and damping value
-20° F to +160° F without heater
(-29° C to +71° C) and thermostat
-40° F to +160° F with heater and
(-40° C to +71° C) thermostat
± .01%/degree F
(± .018%/degree C)
Standard: 2500 Feet (760 M)
Intrinsically Safe: 800 Feet (240 M)
25