English
Language : 

82562V Datasheet, PDF (9/42 Pages) Intel Corporation – 10/100 Mbps Platform LAN Connect
3.1.2
3.2
Networking Silicon — 82562V
Enhanced Tx Mode
The enhanced Tx mode speeds up the rise and fall times of the 100 Mb signal. This was done so the
82562V can have improved IEEE PHY conformance requirements over a more capacitive Analog
Front End (AFE); usually caused by long traces or differential switches that customers use, usually
on mobile platforms. However, running an 82562V device in enhanced mode increases the radiated
emissions seen from the LAN solution. The increase in radiated emissions may or may not impact
the DUT’s ability to pass regulatory requirements, as it will depend largely on the design of the
AFE. The enhanced mode should only be used when 100Base-TX rise/fall times cannot be met in
the normal 82562V mode. Consult an Intel representative if you are considering using this mode.
Management Data Interface MDI/MDI-X
MDI/MDI-X provides the ability to automatically detect the required cable connection type and
configure the controller-side MAU to the cable type. MDI/MDI-X effectively allows all properly
wired Ethernet cables usable with any Ethernet device to be connected to the 82562V without any
additional external logic.
MDI/MDI-X enables auto-correction of incorrect cabling with respect to cross-over versus
straight-through cables. The 82562V can identify the cable connection type and adjust its MDI port
to the cable by switching between the TD and RD pairs. The auto-switching is done prior to the
start of the hardware auto negotiation algorithm.
In a standard straight-through RJ-45 port configuration, the transmit pair is on contacts 1 and 2, and
the receive pair on contacts 3 and 6. These are defined by Clause 23.7.1 of the IEEE 802.3u
standard.
Table 4 lists the connections for both straight-through and cross-over RJ-45 ports for comparison.
Table 4. RJ-45 Connections
RJ-45 Straight-Through MDI
Contact
Signala
Cross-Over MDIX
Signalb
1
TD+
RD+
2
TD-
RD-
3
RD+
TD+
4
Not Used
Not Used
5
Not Used
Not Used
6
RD-
TD-
7
Not Used
Not Used
8
Not Used
Not Used
a. Straight-through connections used on Data Terminal Equipment (DTE)
applications.
b. Cross-over connections used on Hub and Switch applications.
Datasheet
7