5.3.3.2 Low Side Gate Drive (LSGD)
ICB2FL03G
Controller for Fluorescent Lamp Ballasts
Electrical Characteristics
Parameter
Symbol
Limit Values
Unit
Test Conditions
min. typ. max.
LSGD Low Voltage
VLSGDLow
0.4 0.7 1.0
0.4 0.8 1.2
V ILSGD = 5mA1)
V ILSGD = 20mA1)
LSGD High Voltage
VLSGDHigh
–0.3 0.2 0.5
10.0 10.8 11.6
9.0 –
–
V ILSGD = - 20mA (Source)
V
2)
V
3)
8.5 –
–
V
4)
LSGD active Shut Down
LSGD UVLO Shut Down
LSGD Peak Source Current
LSGD Peak Sink Current
LSGD Voltage during 1)
LSGD Rise Time
LSGD Fall Time
1) Sink Current
VLSGDASD
VLSGDUVLO
ILSGDSource
ILSGDSink
VLSGDHigh
tLSGDRise
tLSGDFall
0.4 0.75 1.1
0.3 1.0 1.5
– –50 –
– 300 –
– 11.7 –
100 245 405
20 35 60
V VCC=5V / ILSGD = 20mA1)
V VCC=2V / ILSGD = 5mA1)
mA 5)+6)
mA 5)+6)
V ILSGDsinkH = 3mA
ns 2V < VLSGD < 8V5)
ns 8V > VLSGD > 2V5)
2) ILSGD = - 20mA Source Current
3) VCCOFF + 0.3V and ILSGD = - 1mA Source Current
4) VCCOFF + 0.3V and ILSGD = - 5mA Source Current
5) Load: RLoad = 10Ω and CLoad = 1nF
6) The parameter is not subject to a production test – verified by design / characterization
5.3.3.3 Inverter Control Run (RFRUN)
Parameter
Symbol
Limit Values
min. typ. max.
Fixed Start – Up Frequency
FStartUp
121.5
Duration of Soft Start
tSoftStart
9
RFRUN Voltage in Run Mode
VRFRUN
–
Run Frequency
FRFRUN
49
Adjustable Run Frequency
FRFRUN1
–
FRFRUN2
–
FRFRUN3
–
RFRUN max. Current Range
IRFRUNmax
–
1) Shift Start Up Frequency to Preheating Frequency
135
11
2.5
50
20
40
100
–1000
148.5
13.5
–
51
–
–
–
– 650
Unit
Test Conditions
kHz
ms 1)
V @ 100μA<IRFRUN<600μA
kHz RRFRUN = 10kΩ
kHz IRFRUN = – 100 μA
kHz IRFRUN = – 200 μA
kHz IRFRUN = – 500 μA
μA @ VRFRUN = 0V
Final Data Sheet