Functional Description
2.2.1 Operating Levels from UVLO to Soft Start
This section describes the operating flow from phase 1 (UVLO) to phase 4 (soft start) in detail. The control of the
ballast is able to start the operation within less than 100 ms (IC in active mode). This is achieved by a small start-
up capacitor (about 1 μF C12 and C13 â fed by start-up resistors R11 and R12 in Figure 3) and the low current
consumption during the UVLO (IVCC = 130 μA â phase 1, Figure 5) and start-up hysteresis (IVCC = 160 μA â defines
the start-up resistors â phase 2, Figure 5) phases. The chip supply stage of the IC is protected against overvoltage
via an internal Zener clamping network, which clamps the voltage at 16.3 V and allows a current of 2.5 mA. For
clamping currents above 2.5 mA, an external Zener diode (D9, Figure 3) is required.1)
Frequency /
Lamp Voltage
135 kHz
Frequency
100 kHz
VBU S
100 %
95 %
Lamp Voltage
30 %
VCC
17.5 V
16.0 V
14.0 V
10.6 V
IVCC
VRES
1.6 V
IRES
ILVS
1
UVLO
130 µA
2
Monitoring
3
4
Start Up Soft Start
< 160 µA
< 6.0 mA + IGate
- 21.3 µA
> 18 µA
< 210µApp
Figure 5 Typical Startup Procedure in Run Mode (in Normal Operation)
1) IGate depends on MOSFET