Protection Functions Matrix
Table 3 Protection Functions Matrix (cont’d)
Description of Fault
Characteristics of Fault
Operating Mode Detection Active
Consequence
Run frequency cannot be
achieved
Timeout
ignition
F 237ms
X
Power down, latched
fault mode, 1 restart
Voltage at PFCCS pin >1.0V PFC
overcurrent
N 200ns
X X X X X X Stops on-time of PFC
FET immediately
Voltage at LSCS pin >0.8V Inverter
current lim
N 200ns
X
Activates ignition control
Voltage at LSCS pin >0.8V Inverter
overcurrent
F 500ns
X
X Power down, latched
fault mode, 1 restart
Voltage at LSCS pin >1.6V Inverter
overcurrent
F 500ns
XX
XX
Power down, latched
fault mode, 1 restart
Inverter overcurrent
Surge
A 500ns
X X Power-down, restart
& VBUS > 109% (Surge)
when VBUS < 109 %
After jump into latched fault mode F wait
200ms A single restart attempt after delay of internal timer
Reset of failure latch in run mode after
40s Reset of failure latch by UVLO or 40 s in run mode
S = Start-up condition, N = No fault, A = Auto restart , U = Undervoltage
F = Fault with a single restart; a second F leads to a latched fault
Note: All values @ typical 50 Hz mains frequency
Final Data Sheet
41