Diagnosis Functions
up current source must be initially enabled in order to detect the OLOFF fault. Once this fault is detected, the pull
up current source current can be disabled and the pull down current can be enabled by SPI in order to determine
if the fault is an open load or a short to battery.
The diagnostic currents used are weak, a wait time is needed before the OLOFF bit is read.
twait = (VLSUP /2) * Cload/ |IDIAGMIN|. IDIAGMIN is the absolute value of the IDIAG_UPMax or IDIAG_DNMin depending on which
is selected.
VLSUPx
IDI AG
LOG IC
OL O FFx
filter
+
-
VLSUPx
2
LOADx
CESD
Figure 23 OLSB Fault - Off State Block Diagram
Data Sheet
-
42
Rev 1.0, 2015-03-27