HYB25D512400AT Datasheet, PDF (22/76 Pages) Infineon Technologies AG – 512Mbit Double Data Rate SDRAM
HYB25D512[16/40/80]0AT–[6/7/7F]
Functional Description
3.5.2 Reads
Subsequent to programming the mode register with CAS latency, burst type, and burst length, Read bursts are
initiated with a Read command, as shown on Figure 8.
The starting column and bank addresses are provided with the Read command and Auto Precharge is either
enabled or disabled for that burst access. If Auto Precharge is enabled, the row that is accessed starts precharge
at the completion of the burst, provided tRAS has been satisfied. For the generic Read commands used in the
following illustrations, Auto Precharge is disabled.
During Read bursts, the valid data-out element from the starting column address is available following the CAS
latency after the Read command. Each subsequent data-out element is valid nominally at the next positive or
negative clock edge (i.e. at the next crossing of CK and CK). Figure 9 shows general timing for each supported
CAS latency setting. DQS is driven by the DDR SDRAM along with output data. The initial low state on DQS is
known as the read preamble; the low state coincident with the last data-out element is known as the read
postamble. Upon completion of a burst, assuming no other commands have been initiated, the DQs goes High-Z.
Data from any Read burst may be concatenated with or truncated with data from a subsequent Read command.
In either case, a continuous flow of data can be maintained. The first data element from the new burst follows either
the last element of a completed burst or the last desired data element of a longer burst which is being truncated.
The new Read command should be issued x cycles after the first Read command, where x equals the number of
desired data element pairs (pairs are required by the 2n prefetch architecture). This is shown on Figure 10. A
Read command can be initiated on any clock cycle following a previous Read command. Nonconsecutive Read
data is illustrated on Figure 11. Full-speed Random Read Accesses: CAS Latencies (Burst Length = 2, 4 or 8)
within a page (or pages) can be performed as shown on Figure 12.
CK
CK
CKE
CS
RAS
CAS
WE
x4: A0-A9, A11
x8: A0-A9
x16: A0-A8
A10
BA0, BA1
HIGH
CA
EN AP
DIS AP
BA
Figure 8 Read Command
CA = column address
BA = bank address
EN AP = enable Auto Precharge
DIS AP = disable Auto Precharge
Don’t Care
Data Sheet
22
Rev. 1.0, 2004-03